BackgroundIncremental palmar stimulation of the median nerve sensory conduction at the wrist, the "inching test", provides an assessment with reference to segments proximal and distal to the entrapment. This study used high-resolution ultrasonography (US) to measure the median nerve's cross-section areas (CSAs) like the "inching test" and to correlate with the nerve conduction study (NCS) severity and duration of carpal tunnel syndrome (CTS).MethodsTwo hundred and twelve (212) "CTS-hands" from 135 CTS patients and 50 asymptomatic hands ("A-hands") from 25 control individuals were enrolled. The median nerve CSAs were measured at the 8-point marked as i4, i3, i2, i1, w, o1, o2, and 03 in inching test. The NCS severities were classified into six groups based on motor and sensory responses (i.e., negative, minimal, mild, moderate, severe, and extreme). Results of US studies were compared in terms of NCS severity and duration of clinical CTS symptoms.ResultsThere was significantly larger CSA of the NCS negative group of "CTS-hands" than of "A-hands". The cut-off values of the CSAs of the NCS negative CTS group were 12.5 mm2, 11.5 mm2 and 10.1 mm2 at the inlet, wrist crease, and outlet, respectively. Of the 212 "CTS-hands", 32 were NCS negative while 40 had minimal, 43 mild, 85 moderate, 10 severe, and two extreme NCS severities. The CSAs of "CTS-hands" positively correlated with different NCS severities and with the duration of CTS symptoms. By duration of clinical symptoms, 12 of the 212 "CTS-hands" were in the 1 month group; 82 in >1 month and ≤12 months group, and 118 in >12 months group. In "inching test", segments i4-i3 and i3-i2 were the most common "positive-site". The corresponding CSAs measured at i4 and i3, but not at i2, were significantly larger than those measured at points that were not "positive-site".ConclusionsUsing the 8-point measurement of the median nerve CSA from inlet to outlet similar to the "inching test" has positive correlations with NCS severity and duration of CTS clinical symptoms, and can provide more information on anatomic changes. Combined NCS and US studies using the 8-point measurement may have a higher positive rate than NCS alone for diagnosing CTS.
In the present study, we illustrate the use of an electrophysiological classification as a guide to the treatment of carpal tunnel syndrome (CTS). A total of 113 CTS patients were assessed with symptom severity scores, hand functional scores and electrophysiological studies. By setting criteria of electrophysiological tests, 179 hands in 113 patients were classified into mild, moderate and severe degrees of CTS. Of these, the 41 hands with severe CTS were referred for surgery. The 58 hands with moderate CTS and 80 hands with mild CTS received conservative treatment. The improvement ratios in the severe group were greater than that in the moderate and mild groups, both at 6 months and at 1 year. Eighteen hands with moderate or mild CTS returned to normal electrophysiology with the conservative treatments. No patient recovered to normal electrophysiology in the severe group. This electrophysiological classification is objective and it may serve as a useful guide for non-surgical and surgical treatment of CTS.
BackgroundQ-Sweat is a model used for evaluating the post-ganglionic sudomotor function by assessing sweat response. This study aimed to establish the normative database of Q-Sweat test among Chinese individuals since this type of information is currently lacking.ResultsOne hundred and fifty (150) healthy volunteers, 76 men and 74 women with age range of 22–76 years were included. Skin temperature and sweat onset latency measured at the four sites (i.e., the forearm, proximal leg, distal leg, and the foot) did not significantly correlate with age, gender, body height (BH), body weight (BW), and body mass index (BMI) but the total sweat volume measured in all four sites significantly correlated with sex, BH, and BW. Except for the distal leg, the total sweat volume measured at the other three sites had a significant correlation with BMI. In terms of gender, men had larger total sweat volume, with median differences at the forearm, proximal leg, distal leg, and foot of 0.591 μl, 0.693 μl, 0.696 μl, and 0.358 μl, respectively. Regarding BW difference (≥62 and < 62 Kg), those with BW ≥62 Kg had larger total sweat volume. Median differences at the forearm, proximal leg, distal leg, and foot were 0.538 μl, 0.744 μl, 0.695 μl, and 0.338 μl, respectively. There was an uneven distribution of male and female participants in the two BW groups. In all conditions, the total sweat volume recorded at the foot site was the smallest.ConclusionThis is the first report to show the normative database of sweat response in Chinese participants evaluated using Q-Sweat device. This normative database can help guide further research on post-ganglionic sudomotor or related clinical practice involving a Chinese population.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.