On the basis of present evidence, intracoronary BMC infusion in patients with AMI seems to be safe and associated with slight improvement of the left ventricular ejection fraction at 3-6 months' follow-up.
Transplantation of either MNC or EPC may be beneficial to cardiac systolic function, but might not has obvious effect on diastolic function. Intracoronary infusion of EPC might be better than MNC in controlling infarction size. Both MNC and EPC may stimulate angiogenesis, inhibit fibrogenesis, and differentiate into myocardial cells.
ObjectivesThe study reports the final 5‐year safety and effectiveness outcomes of the novel abluminal groove‐filled biodegradable polymer‐coated FIREHAWK sirolimus‐eluting stent in a large patient cohort.BackgroundThe TARGET clinical program was conducted to evaluate the performance of the FIREHAWK stent, and this objective performance criterion study pooled long‐term safety and efficacy data from three TARGET trials for greater statistical power to analyze low‐frequency events.MethodsPatient‐level pooled data from 1,007 individuals in the TARGET I randomized controlled trial (n = 227), TARGET I long lesion cohort (n = 50), and TARGET II registry (n = 730) were prospectively collected and analyzed. The primary endpoint, target lesion failure (TLF), was defined as a composite of cardiac death, target vessel myocardial infarction (TV‐MI), and ischemia‐driven indicated target lesion revascularization (ID‐TLR) at 5 years. All patients were exclusively treated with the FIREHAWK stent and had annual follow‐up visits for up to 5 years.ResultsAmong 947 patients (94.0%) who completed the 5‐year clinical follow‐up, the 5‐year TLF event rate was 8.1%; the events included 18 cardiac deaths, 36 TV‐MIs, and 33 ID‐TLRs. Only four (0.4%) very late probable or definite stent thrombosis events were observed beyond 1 year after stent implantation. In the subgroup analysis, lesion length ≥ 30 mm was associated with higher long‐term TLF incidence, while the use of a predilation‐sizing‐postdilation technique showed no significant effect on long‐term outcomes.ConclusionsFive‐year results demonstrate the continuing safety and efficacy of the FIREHAWK Stent, with relatively lower incidence of thrombotic events.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.