We have devised a simple enzyme immunoassay (EIA) that detects increasing levels of anti-HIV IgG after seroconversion and can be used for detecting recent HIV-1 infection. Use of a branched peptide that included gp41 immunodominant sequences from HIV-1 subtypes B, E, and D allowed similar detection of HIV-specific antibodies among various subtypes. Because of the competitive nature of the capture EIA, a gradual increase in the proportion of HIV-1-specific IgG in total IgG was observed for 2 years after seroconversion. This was in contrast to results obtained with the conventional EIA using the same antigen in solid phase, which plateaus soon after seroconversion. The assay was used to test 622 longitudinal specimens from 139 incident infections in the United States (subtype B) and in Thailand (subtypes B and E). The assay was also performed with an additional 8 M urea incubation step to assess the contribution of high-avidity antibodies. Normalized optical density (OD-n) was calculated (ODspecimen/ODcalibrator), using a calibrator specimen. An incremental analysis indicated that a cutoff of 1.0 OD-n and a seroconversion period of 160 days offered the best combination of sensitivity and specificity for classifying incident or long-term infections. The urea step increased the seroconversion period to 180 days with similar sensitivity and specificity. Separate analysis of B and E subtype specimens yielded the same optimal OD-n threshold and similar seroconversion periods. The assay was further validated in African specimens (subtypes A, C, and D) where the observed incidence was within 10% of the expected incidence. This assay should be useful for detecting recent HIV-1 infection and for estimating incidence among diverse HIV-1 subtypes worldwide.
Recently, we developed an immunoglobulin G (IgG)-capture BED-enzyme immunoassay (BED-CEIA) to identify recent human immunodeficiency virus (HIV) type 1 (HIV-1) seroconversion for use in incidence estimates. We have established an algorithm for its use; developed quality control reagents to monitor the assay; and evaluated its performance for interrun, intrarun, and operator variability. Analysis of 144 individual plates, which involved multiple plate lots and several operators over more than a year, indicated that the coefficients of variation (CVs) were between 10 and 15% for raw optical density (OD) values in the dynamic range between 0.5 and 2.0 OD units; the CVs decreased to 5 to 10% when the OD was normalized (OD-n; OD-n ؍ specimen OD/calibrator OD). The intrarun CVs were generally in the range of 5 to 10% for specimens with ODs <0.5 and less than 5% for specimens with ODs >0.5. The level of concordance between multiple plate lots (n ؍ 6) and multiple operators (n ؍ 7) was quite high (R 2 > 0. 9). Comparison of the results of the initial and the confirmatory tests with specimens with OD-n values
Serodiagnosis of human immunodeficiency virus (HIV) infection in the UnitedStates has traditionally relied on a sequential two-test algorithm: an initial screen with an enzyme immunoassay (EIA) and reflex testing of EIA-reactive specimens with a more specific supplemental test such as Western blotting or immunofluorescence. The supplemental tests are tedious, subjective, and expensive. In addition, there have been major improvements in the performance and accuracy of the EIA tests as well as the introduction of rapid serologic tests (RT) and HIV nucleic acid amplification tests (NAAT). Related to these improvements is the possibility that alternative algorithms using combinations of currently approved HIV tests may function as well as if not better than the current algorithm, with more flexibility, improved accuracy, and lower cost. To this end, we evaluated the performance of 12 currently licensed tests and 1 in-house HIV test (6 EIA, 4 RT, and 3 NAAT) on panels of plasma samples from HIV-infected (n ؍ 621 HIV type 1 [HIV-1] and 34 HIV-2) and uninfected (n ؍ 513) people and of sequential specimens from people early in seroconversion (183 specimens from 15 patients). Test combinations were analyzed in two dual-test (sensitivity-optimized and specificity-optimized) algorithms and in a three-test (tie-breaking) algorithm, and performance was compared to the conventional algorithm. The results indicate that alternative algorithm strategies with currently licensed tests compare favorably with the conventional algorithm in detecting and confirming established HIV infection. Furthermore, there was a lower frequency of discordant or indeterminate results that require follow-up testing, and there was improved detection of early infection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.