Piezoelectric materials can convert mechanical energy into electrical energy, and piezoelectric devices made of a variety of inorganic materials and organic polymers have been demonstrated. However, synthesizing such materials often requires toxic starting compounds, harsh conditions and/or complex procedures. Previously, it was shown that hierarchically organized natural materials such as bones, collagen fibrils and peptide nanotubes can display piezoelectric properties. Here, we demonstrate that the piezoelectric and liquid-crystalline properties of M13 bacteriophage (phage) can be used to generate electrical energy. Using piezoresponse force microscopy, we characterize the structure-dependent piezoelectric properties of the phage at the molecular level. We then show that self-assembled thin films of phage can exhibit piezoelectric strengths of up to 7.8 pm V(-1). We also demonstrate that it is possible to modulate the dipole strength of the phage, hence tuning the piezoelectric response, by genetically engineering the major coat proteins of the phage. Finally, we develop a phage-based piezoelectric generator that produces up to 6 nA of current and 400 mV of potential and use it to operate a liquid-crystal display. Because biotechnology techniques enable large-scale production of genetically modified phages, phage-based piezoelectric materials potentially offer a simple and environmentally friendly approach to piezoelectric energy generation.
Many materials in nature change colours in response to stimuli, making them attractive for use as sensor platform. However, both natural materials and their synthetic analogues lack selectivity towards specific chemicals, and introducing such selectivity remains a challenge. Here we report the self-assembly of genetically engineered viruses (M13 phage) into targetspecific, colourimetric biosensors. The sensors are composed of phage-bundle nanostructures and exhibit viewing-angle independent colour, similar to collagen structures in turkey skin. On exposure to various volatile organic chemicals, the structures rapidly swell and undergo distinct colour changes. Furthermore, sensors composed of phage displaying trinitrotoluene (TNT)-binding peptide motifs identified from a phage display selectively distinguish TNT down to 300 p.p.b. over similarly structured chemicals. Our tunable, colourimetric sensors can be useful for the detection of a variety of harmful toxicants and pathogens to protect human health and national security.
The selective detection of a specific target molecule in a complex environment containing potential contaminants presents a significant challenge in chemical sensor development. Utilizing phage display techniques against trinitrotoluene (TNT) and dinitrotoluene (DNT) targets, peptide receptors have previously been identified with selective binding capabilities for these molecules. For practical applications, these receptors must be immobilized onto the surface of sensor platforms at high density while maintaining their ability to bind target molecules. In this paper, a polymeric matrix composed of poly(ethylene-co-glycidyl methacrylate) (PEGM) has been prepared. A high density of receptors was covalently linked through reaction of amino groups present in the receptor with epoxy groups present in the co-polymer. Using X-ray photoelectron spectroscopy (XPS) and gas-chromatography/mass spectroscopy (GC/MS), this attachment strategy is demonstrated to lead to stably bound receptors, which maintain their selective binding ability for TNT. The TNT receptor/PEGM conjugates retained 10-fold higher TNT binding ability in liquid compared to the lone PEGM surface and 3-fold higher TNT binding compared to non-specific receptor conjugates. In contrast, non-target DNT exposure yielded undetectable levels of binding. These results indicate that this polymeric construct is an effective means of facilitating selective target interaction both in an aqueous environment. Finally, real-time detection experiments were performed using a quartz crystal microbalance (QCM) as the sensing platform. Selective detection of TNT vs DNT was demonstrated using QCM crystals coated with PEGM/TNT receptor, highlighting that this receptor coating can be incorporated as a sensing element in a standard detection device for practical applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.