SummaryFifty-six patients scheduled for total hip alloplasty were screened for deep venous thrombosis by means of 99mTc-plasmin scintimetry, 99mTc-plasmin scintigraphy and contact thermography. Investigations were performed on the seventh postoperative day, and a total of 112 legs were examined. Bilateral ascending phlebography was used as reference procedure, and the criteria for deep venous thrombosis were intraluminal filling defects at phlebography. Six patients developed unilateral deep venous thrombosis. All three screening procedures revealed many false positive and several false negative results. The nosographic sensitivity/specificity was 33%/75% for scintimetry, 50%/91% for scintigraphy and 33%/87% for contact thermography, respectively. It is concluded that all three tests are of no value as screening methods for deep venous thrombosis following major elective hip surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.