Introduction: In critically ill patients, nasogastric (NG) and nasojejunal (NJ) feeding tube placements are standard procedures. However, about 1.9% of blind tube insertions are malpositioned in the tracheopulmonary system, whereas guided procedures may result in a significant delay in nutritional delivery. Guided methods, such as Cortrak and fluoroscopy, have success rates of 82.6e85% and 93% respectively. The current study aims to investigate the performance of video-assisted feeding tube placement in the post-pyloric position using Integrated Real Time Imaging System (IRIS-) technology. Methods: A prospective cohort study in patients requiring enteral feeding was conducted in a mixed medical-surgical intensive care unit (ICU). The primary outcome was the post-pyloric placement of IRIS feeding tubes, as confirmed by X-ray. Secondary study objectives included gastric placement, ease of use and adverse events. Results: Thirty-one feeding tubes were placed using IRIS-technology; one patient was excluded for analysis due to protocol violation. One procedure was terminated due to significant bleeding (epistaxis) and desaturation. Only eighteen (58%) feeding tubes were placed in post-pyloric position (including two past the ligament of Treitz). In subjects who needed post-pyloric placement due gastroparesis, IRIS was mostly unsuccessful (success rate of 25%). However, when gastric placement was the primary objective, 96.8% of tubes were correctly placed. During insertion, tracheal visualization occurred in 27% of cases, and the IRIS feeding tube was repositioned early in the procedure without causing patient harm. Conclusions: Real-time video-assisted post-pyloric feeding tube placement in critically ill ICU patients was only successful in 58% of cases and therefore currently cannot be recommended for this indication. However, a high success rate (96.8%) for gastric placement was achieved. IRIS tube placement detected tracheal misplacement immediately and had few adverse events.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.