This study aimed to investigate the validity and reliability of global (GPS) and local (LPS) positioning systems for measuring distances covered and sprint mechanical properties in team sports. Here, we evaluated two recently released 18 Hz GPS and 20 Hz LPS technologies together with one established 10 Hz GPS technology. Six male athletes (age: 27±2 years; VO2max: 48.8±4.7 ml/min/kg) performed outdoors on 10 trials of a team sport-specific circuit that was equipped with double-light timing gates. The circuit included various walking, jogging, and sprinting sections that were performed either in straight-lines or with changes of direction. During the circuit, athletes wore two devices of each positioning system. From the reported and filtered velocity data, the distances covered and sprint mechanical properties (i.e., the theoretical maximal horizontal velocity, force, and power output) were computed. The sprint mechanical properties were modeled via an inverse dynamic approach applied to the center of mass. The validity was determined by comparing the measured and criterion data via the typical error of estimate (TEE), whereas the reliability was examined by comparing the two devices of each technology (i.e., the between-device reliability) via the coefficient of variation (CV). Outliers due to measurement errors were statistically identified and excluded from validity and reliability analyses. The 18 Hz GPS showed better validity and reliability for determining the distances covered (TEE: 1.6–8.0%; CV: 1.1–5.1%) and sprint mechanical properties (TEE: 4.5–14.3%; CV: 3.1–7.5%) than the 10 Hz GPS (TEE: 3.0–12.9%; CV: 2.5–13.0% and TEE: 4.1–23.1%; CV: 3.3–20.0%). However, the 20 Hz LPS demonstrated superior validity and reliability overall (TEE: 1.0–6.0%; CV: 0.7–5.0% and TEE: 2.1–9.2%; CV: 1.6–7.3%). For the 10 Hz GPS, 18 Hz GPS, and 20 Hz LPS, the relative loss of data sets due to measurement errors was 10.0%, 20.0%, and 15.8%, respectively. This study shows that 18 Hz GPS has enhanced validity and reliability for determining movement patterns in team sports compared to 10 Hz GPS, whereas 20 Hz LPS had superior validity and reliability overall. However, compared to 10 Hz GPS, 18 Hz GPS and 20 Hz LPS technologies had more outliers due to measurement errors, which limits their practical applications at this time.
The aim of the study was to quantify the association between match running performance and success across a season in soccer teams competing within a European top league. We analyzed the match running performance data of all soccer teams from the German Bundesliga across the season 2012/13 (306 matches). The following match running performance data were used: total distance covered as well as number of running activities>18.0 km/h and > 22.7 km/h. Depending on the team's ball possession status, all match running performance data were also analyzed as those with and without ball possession. The success across the season was defined as the final competition points accumulated. The match running performance alone was not significantly correlated with the final points accumulated (best r=0.24; p=0.34). In contrast, positive-significant correlations were observed for the match running performance with ball possession (best r=0.77; p<0.01). However, of these latter correlations, only the total distance covered with ball possession was a significant predictor (p<0.01) and accounted for 60% of the variance (R(2)=0.60) in the final points accumulated. It is concluded that it is not the match running performance alone that is important for achieving success in German Bundesliga soccer teams, but rather its relation to technical/tactical skills with respect to ball possession.
When considering the scientific lack concerning the execution and acute effects and mechanism of foam rolling (FR), this study has evaluated the biomechanical loads by the force-time characteristics during two popular FR exercises. Additionally, the acute effects of FR on jump height and muscular stiffness were simultaneously assessed. Within a randomized cross-over design, 20 males (26.6 ± 2.7 years; 181.6 ± 6.8 cm; 80.4 ± 9.1 kg) were tested on different days pre, post, and 15 and 30 min after three interventions. The interventions consisted of a FR procedure for the calf and anterior thigh of both legs, 10 min ergometer cycling, and resting as a control. Stiffness was measured via mechanomyography at the thigh, calf, and ankle. The vertical ground reaction forces were measured under the roller device during FR as well as to estimate jump height. Within the FR exercises, the forces decreased from the proximal to distal position, and were in mean 34 and 32% of body weight for the calves and thighs, respectively. Importantly, with 51 to 55%, the maxima of the individual mean forces were considerably higher. Jump height did not change after FR, but increased after cycling. Moreover, stiffness of the thigh decreased after FR and increased after cycling.
ACL reconstructed patients showed GRF asymmetries during unilateral and bilateral movements of different knee loads. Three compensation strategies were found in patients with low subjective knee function: (1) a reduced eccentric load, (2) an inter-limb compensation during bilateral movements, and (3) the avoidance of high vertical impact forces. These compensation strategies may be indicative of a protective adaptation to avoid excessive ACL strain. GRF measurements are practicable and efficient tools to identify individual compensation strategies during early rehabilitation.
BackgroundStrength deficits, muscle imbalances, and quadriceps inhibition are common after the surgical reconstruction of the anterior cruciate ligament (ACL), even after the patient’s returned-to-sport. Typically, asymmetries between the operated and non-operated leg as well as the hamstring/quadriceps (HQ) ratio are calculated using maximum isokinetic torque values. Moreover, the knee flexion angles, which correspond to the measured torque values, were not considered. Therefore, the aim of the study was to evaluate the usage of an angle-specific approach for the analysis of isokinetic data in patients after an ACL-reconstruction.MethodsA cross-sectional laboratory study design was used to investigate the influence of leg (operated vs. non-operated) and two velocities on angle-specific isokinetic data. Concentric quadriceps and hamstring torques and ratios of 38 patients were assessed 6.6 months after ACL-reconstruction with a hamstring tendon graft. At a velocity of 60°/s and 180°/s, angle-specific torques and HQ-ratios were analyzed with conventional discrete parameters and a Statistical Parametric Mapping procedure, which evaluates continuous data. The relationship between angle-specific and conventional HQ-ratios was evaluated with Pearson correlation coefficients.ResultsAngle-specific torques and HQ-ratios were different between the operated and non-operated leg and between velocities. In the operated leg, the quadriceps deficit was higher at 60°/s in knee flexion angles > 50°. The HQ-ratios decreased with greater knee flexion at both velocities, but with a different magnitude. Around 30°, the HQ-ratios reached 1.0 and did not differ between the velocities, while leg differences were present from 40 to 60°. At the higher testing velocity, the maximum flexion torque occurred at greater knee flexion, whereas the maximum extension torque were present at a similar joint angle. The correlation coefficients between conventional and angle-specific HQ-ratios were low in knee angles < 35° and > 65° and varied according to leg and velocity.ConclusionsThe angle specific approach is recommended for future ACL-research, as it reveals strength deficits and imbalances, which were not captured by conventional parameters. The results provide a rationale for more specific joint angle and/or velocity based training and may help for return-to-sport decisions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.