The emerging profile of blood flow and the cross-sectional distribution of blood cells have far reaching biological consequences in various diseases and vital internal processes, such as platelet adhesion. The effects of several essential blood flow parameters, such as red blood cell free layer width, wall shear rate, and hematocrit on platelet adhesion were previously explored to great lengths in straight geometries. In the current work, the effects of channel curvature on cellular blood flow are investigated by simulating the accurate cellular movement and interaction of red blood cells and platelets in a half-arc channel for multiple wall shear rate and hematocrit values. The results show significant differences in the emerging shear rate values and distributions between the inner and outer arc of the channel curve, while the cell distributions remain predominantly uninfluenced. The simulation predictions are also compared to experimental platelet adhesion in a similar curved geometry. The inner side of the arc shows elevated platelet adhesion intensity at high wall shear rate, which correlates with increased shear rate and shear rate gradient sites in the simulation. Furthermore, since the platelet availability for binding seems uninfluenced by the curvature, these effects might influence the binding mechanics rather than the probability. The presence of elongational flows is detected in the simulations and the link to increased platelet adhesion is discussed in the experimental results.
To analyze flow conditions and cellular behavior at the onset of a hemostatic response in the injury of a microneedle-induced vessel puncture, a combinedin silicoandin vitroplatform is created. A cell-resolved blood flow model is utilized for in-depth flow profile and cell distribution analyses and a novel punctured vessel flow chamber is set up to complement the simulations with the evaluation of platelet aggregation around the wound neck of the puncture. The respective setups of the platform are explained and the results of both experiments and simulations with various puncture diameters and pressure drops are combined, providing detailed insight into the basic processes of platelet transport and aggregation in the wound area. A special emphasis of the simulation evaluation is put on the cell distributions and the magnitude of shear rate and elongational flow in the wound neck area, as well as downstream from the puncture. Additionally, possible implications of wound size and pressure difference on the hemostatic response are discussed. The simulations display asymmetric cell distributions between the proximal and distal side of the wound neck in regards to flow direction. The flow chamber with the puncture diameter closest to the simulated domains confirms this asymmetry by displaying increased platelet aggregation at the wound neck’s distal side. The presented punctured vesselin silicoandin vitroexperimental setups offer a platform to analyze the hemostatic environment of a vessel injured by a puncture and might assist in identifying differentiating factors between primary hemostasis and arterial thrombosis.
To analyze flow conditions and cellular behavior at the onset of a hemostatic response in the injury of a microneedle-induced vessel puncture, a combined in silico and in vitro platform is created. A cell-resolved blood flow model is utilized for in-depth flow profile and cell distribution analyses, and a novel punctured vessel flow chamber is set up to complement the simulations with the evaluation of platelet aggregation around the wound neck of the puncture. The respective setups of the platform are explained, and the results of both experiments and simulations with various puncture diameters and pressure drops are combined, providing detailed insight into the basic processes of platelet transport and aggregation in the wound area. A special emphasis of the simulation evaluation is put on the cell distributions and the magnitude of shear rate and elongational flow in the wound neck area, as well as downstream from the puncture. Additionally, possible implications of wound size and pressure difference on the hemostatic response are discussed. The simulations display asymmetric cell distributions between the proximal and distal sides of the wound neck in regard to the flow direction. The flow chamber with the puncture diameter closest to the simulated domains confirms this asymmetry by displaying increased platelet aggregation at the wound neck's distal side. The presented punctured vessel in silico and in vitro experimental setups offer a platform to analyze the hemostatic environment of a vessel injured by a puncture and might assist in identifying differentiating factors between primary hemostasis and arterial thrombosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.