bronchoscopy during the COVID-19 pandemic: A four-center collaborative protocol to improve safety with perioperative management strategies and creation of a surgical tent with disposable drapes, International Journal of Pediatric Otorhinolaryngology, https://doi.are co-senior authors Running Title: Bronchoscopy during the COVID-19 pandemic.Word Count: 3671 words.
Abstract:Aerosolization procedures during the COVID-19 pandemic place all operating room personnel at risk for exposure. We offer detailed perioperative management strategies and present a specific protocol designed to improve safety during pediatric laryngoscopy and bronchoscopy. Several methods of using disposable drapes for various procedures are described, with the goal of constructing a tent around the patient to decrease widespread contamination of dispersed droplets and generated aerosol. The concepts presented herein are translatable to future situations where aerosol generating procedures increase risk for any pathogenic exposure. This protocol is a collaborative effort based on knowledge gleaned from clinical and simulation experience from Children's Hospital Colorado, Children's Hospital of Philadelphia, The Hospital for Sick Children in Toronto, and Boston Children's Hospital.
Objectives
With the evolution of medical and surgical management for pediatric airway disorders, the development of easily translated techniques of measuring airway dimensions can improve the quantification of outcomes of these interventions. We have developed a technique that improves the ability to characterize endoscopic airway dimensions using common bronchoscopic equipment and an open-source image-processing platform.
Methods
We validated our technique of Endoscopic Airway Measurement (EAM) using optical instruments in simulation tracheas. We then evaluated EAM in a large animal model (Ovis aries, n = 5), comparing tracheal dimensions obtained with EAM to measurements obtained via 3-D fluoroscopic reconstruction. The animal then underwent resection of the measured segment, and direct measurement of this segment was performed and compared to radiographic measurements and those obtained using EAM.
Results
The simulation tracheas had a direct measurement of 13.6, 18.5, and 24.2 mm in diameter. The mean difference of diameter in simulation tracheas between direct measurements and measurements obtained using EAM was 0.70 ± 0.57 mm. The excised ovine tracheas had an average diameter of 18.54 ± 0.68 mm. The percent difference in diameter obtained from EAM and from 3-D fluoroscopic reconstruction when compared to measurement of the excised tracheal segment was 4.98 ± 2.43% and 10.74 ± 4.07% respectively. Comparison of these three measurements (EAM, measurement of resected trachea, 3-D fluoroscopic reconstruction) with repeated measures ANOVA demonstrated no statistical significance.
Conclusions
Endoscopic airway measurement (EAM) provides equivalent measurements of the airway with the improved versatility of measuring non-circular and multi-level dimensions. Using optical bronchoscopic instruments and open-source image-processing software, our data supports preclinical and clinical translation of an accessible technique to provide objective quantification of airway diameter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.