Interventional radiology/cardiology is one of the fields with the highest radiation doses for workers. For this reason, the International Commission on Radiological Protection (ICRP) published new recommendations in 2018 to shield staff from radiation. This study sets out to establish the extent to which these recommendations are observed in Germany. For the study, areas were selected which are known to have relatively high radiation exposure along with good conditions for radiological protection—interventional cardiology, radiology and vascular surgery. The study was advertised with the aid of an information flyer which was distributed via organisations including the German Cardiac Society (Deutsche Gesellschaft für Kardiologie- Herz- und Kreislaufforschung e. V.). Everyone who participated in our study received a questionnaire to record their occupational medical history, dosimetry, working practices, existing interventional installations and personal protective equipment. The results were compared with international recommendations, especially those of the ICRP, based on state-of-the-art equipment. A total of 104 respondents from eight German clinics took part in the survey. Four participants had been medically diagnosed with cataracts. None of the participants had previously worn an additional dosimeter over their apron to determine partial-body doses. The interventional installations recommended by the ICRP have not been fitted in all examination rooms and, where they have been put in place, they are not always used consistently. Just 31 participants (36.6%) stated that they “always” wore protective lead glasses or a visor. This study revealed considerable deficits in radiological protection—especially in connection with shielding measures and dosimetric practices pertaining to the head and neck—during a range of interventions. Examination rooms without the recommended interventional installations should be upgraded in the future. According to the principle of dose minimization, there is considerable potential for improving radiation protection. Temporary measurements should be taken over the apron to determine the organ-specific equivalent dose to the lens of the eye and the head.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.