In accomplishing successful electrospray ionization analyses, it is imperative to have an understanding of the effects of variables such as analyte structure, instrumental parameters, and solution composition. Here, we review some fundamental studies of the ESI process that are relevant to these issues. We discuss how analyte chargeability and surface activity are related to ESI response, and how accessible parameters such as nonpolar surface area and reversed phase HPLC retention time can be used to predict relative ESI response. Also presented is a description of how derivitizing agents can be used to maximize or enable ESI response by improving the chargeability or hydrophobicity of ESI analytes. Limiting factors in the ESI calibration curve are discussed. At high concentrations, these factors include droplet surface area and excess charge concentration, whereas at low concentrations ion transmission becomes an issue, and chemical interference can also be limiting. Stable and reproducible non-pneumatic ESI operation depends on the ability to balance a number of parameters, including applied voltage and solution surface tension, flow rate, and conductivity. We discuss how changing these parameters can shift the mode of ESI operation from stable to unstable, and how current-voltage curves can be used to characterize the mode of ESI operation. Finally, the characteristics of the ideal ESI solvent, including surface tension and conductivity requirements, are discussed. Analysis in the positive ion mode can be accomplished with acidified methanol/water solutions, but negative ion mode analysis necessitates special constituents that suppress corona discharge and facilitate the production of stable negative ions.
In electrospray ionization (ESI), droplets with a surface excess charge are created. The rate of production of surface excess charge is a constant and is equal to the rate of ion production. The ions appearing in the mass spectrum are postulated to be those that formed the surface excess charge at the time of droplet formation (or their collision products). An equilibrium model based on competition among the ions in the solution for the limited number of excess charge sites has been developed. This model accurately predicts the response curves of singly-charged ionic analytes as a function of the concentration of electrolyte and other analytes and provides an explanation for the selective effectiveness of ESI. At low concentrations of total analyte (micromolar and less), the response curves are linear, indifferent to the presence of other low concentration analytes, and suppressed by electrolyte concentrations in excess of the minimum required. At higher analyte concentrations, the response becomes independent of analyte concentration but highly affected by the presence of other analytes.
Nonpolar regions in biological molecules are investigated as a determining factor governing their electrospray ionization (ESI) mass spectrometric response. Response is compared for a series of peptides whose C-terminal residue is varied among amino acids with increasingly nonpolar side chains. Increased ESI response is observed for peptides with more extensive nonpolar regions. The basis for this increase is examined by comparing values of nonpolar surface area and Gibbs free energy of transfer for the different amino acid residues. Comparisons of response with octadecylamine are also made, and this highly surface-active ion is observed to outcompete all other analytes in ESI response. These observations are rationalized on the basis of the equilibrium partitioning model, which is used successfully to fit experimental data throughout the concentration range for several two-analyte systems. This model suggests that because excess charge exists on ESI droplet surfaces, an analyte's relative affinity for the droplet surface determines its relative ESI response. Increased nonpolar character, which leads to enhanced affinity for the surface phase, results in more successful competition for excess charge and higher ESI response.
The effect of salt concentration on analyte response using electrospray ionization mass spectrometry (ESI-MS) was measured and compared to that predicted by Enke's equilibrium partitioning model. The model predicts that analyte response will be proportional to concentration and that the response factor will decrease with increasing electrolyte concentration. The measured analyte response is proportional to concentration over four orders of magnitude when the electrolyte concentration is below 10(-3) M, as the model predicts. The concentration of excess charge ([Q]) generated by the ESI process increases significantly at 10(-3) M ionic concentration, but the response factor decreases at this concentration. Changes in shape of the spray that cause a loss of ion transmission efficiency may be the basis for the decrease in response. An increase in the analyte response factor with increasing electrolyte concentration is observed for electrolyte concentrations below 10(-3) M. An explanation for this based on the electrical double layer is proposed.
The effect of gas-phase proton transfer reactions on the mass spectral response of solvents and analytes with known gas-phase proton affinities was evaluated. Methanol, ethanol, propanol and water mixtures were employed to probe the effect of gas-phase proton transfer reactions on the abundance of protonated solvent ions. Ion-molecule reactions were carried out either in an atmospheric pressure electrospray ionization source or in the central quadrupole of a triple-quadrupole mass spectrometer. The introduction of solvent vapor with higher gas-phase proton affinity than the solvent being electrosprayed caused protons to transfer to the gasphase solvent molecules. In mixed solvents, protonated solvent clusters of the solvent with higher gas-phase proton affinity dominated the resulting mass spectra. The effect of solvent gas-phase proton affinity on analyte response was also investigated, and the analyte response was suppressed or eliminated in solvents with gas-phase proton affinities higher than that of the analyte.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.