IntroductionSepsis remains associated with a high mortality rate. Endotoxin has been shown to influence viscoelastic coagulation parameters, thus suggesting a link between endotoxin levels and the altered coagulation phenotype in septic patients. This study evaluated the effects of systemic polyspecific IgM-enriched immunoglobulin (IgM-IVIg) (Pentaglobin® [Biotest, Dreieich, Germany]) on endotoxin activity (EA), inflammatory markers, viscoelastic and conventional coagulation parameters.MethodsPatients with severe sepsis were identified by daily screening in a tertiary, academic, surgical ICU. After the inclusion of 15 patients, the application of IgM-IVIg (5 mg/kg/d over three days) was integrated into the unit’s standard operation procedure (SOP) to treat patients with severe sepsis, thereby generating “control” and “IgM-IVIg” groups. EA assays, thrombelastometry (ROTEM®) and impedance aggregometry (Multiplate®) were performed on whole blood. Furthermore, routine laboratory parameters were determined according to unit’s standards.ResultsData from 26 patients were included. On day 1, EA was significantly decreased in the IgM-IVIg group following 6 and 12 hours of treatment (0.51 ±0.06 vs. 0.26 ±0.07, p<0.05 and 0.51 ±0.06 vs. 0.25 ±0.04, p<0.05) and differed significantly compared with the control group following 6 hours of treatment (0.26 ±0.07 vs. 0.43 ±0.07, p<0.05). The platelet count was significantly higher in the IgM-IVIg group following four days of IgM-IVIg treatment (200/nl ±43 vs. 87/nl ±20, p<0.05). The fibrinogen concentration was significantly lower in the control group on day 2 (311 mg/dl ±37 vs. 475 mg/dl ±47 (p = 0.015)) and day 4 (307 mg/dl ±35 vs. 420 mg/dl ±16 (p = 0.017)). No differences in thrombelastometric or aggregometric measurements, or inflammatory markers (interleukin-6 (IL-6), leukocyte, lipopolysaccharide binding protein (LBP)) were observed.ConclusionTreatment with IgM-enriched immunoglobulin attenuates the EA levels in patients with severe sepsis and might have an effect on septic thrombocytopenia and fibrinogen depletion. Viscoelastic, aggregometric or inflammatory parameters were not influenced.Trial Registrationclinicaltrials.gov NCT02444871
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.