Introduction
Ultrasonography may be valuable in staging carpal tunnel syndrome severity, especially by combining multiple measures. This study aimed to develop a preliminary severity staging model using multiple sonographic and clinical measures.
Methods
Measures were obtained in 104 participants. Multiple categorization structures for each variable were correlated to diagnostic severity based on nerve conduction. Goodness-of-fit was evaluated for models using iterative combinations of highly correlated variables. Using the best-fit model, a preliminary scoring system was developed, and frequency of misclassification was calculated.
Results
The severity staging model with best fit (Rho 0.90) included patient-reported symptoms, functional deficits, provocative testing, nerve cross-sectional area, and nerve longitudinal appearance. An 8-point scoring scale classified severity accurately for 79.8% of participants.
Discussion
This severity staging model is a novel approach to carpal tunnel syndrome evaluation. Including more sensitive measures of nerve vascularity, nerve excursion, or other emerging techniques may refine this preliminary model.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.