Purpose: Carbon fibre treatment couches on linear accelerators provide a strong, rigid framework for patient support. Patient safety is a priority, therefore the dosimetric properties of treatment couches need to be accurately incorporated in treatment plans, to minimize differences between planned and delivered dose. This study aims to determine the attenuation effect of treatment couches for 3-D Conformal Radiotherapy (3-D CRT) and to validate the implementation thereof in the XiO and Monaco treatment planning systems (TPS).Material and methods: Attenuation measurements were performed on the ELEKTA Connexion couches of the ELEKTA Precise and Synergy-Agility linear accelerators. Measurements were made at 10° intervals in RMI-457 Solid water (30 cm x 30 cm x 30 cm) using a PTW Farmer-type ionization chamber (TW30013) positioned at the accelerator’s isocentre. The percentage attenuation was calculated as the ratio of the electrometer readings for parallel-opposed fields. The Computed Tomography (CT) data sets of the set-ups were obtained on a Philips Big Bore 16-slice CT scanner and exported to the TPS. The individual couch structures were delineated and electron density (ED) values were assigned using the commissioned CT-to-ED curve. Test treatment plans were generated with 100MU per field at 10° gantry intervals.Results: The percentage attenuation was determined to be within 2% and 3% for beams perpendicular to the couch surface for XiO and Monaco, respectively. The maximum attenuation was observed for oblique fields which was significantly higher than the manufacturer specified values. TPS validation showed an agreement to 1% for XiO and Monaco. At extreme oblique angles, both planning systems overestimated this effect up to a maximum of 4%.Conclusions: Couch attenuation differs significantly with gantry angle and beam energy. As a result, the treatment couch models should be included in all treatment planning calculations.
The gamma analysis metric is a commonly used metric for VMAT plan evaluation. The major drawback of this is the lack of correlation between gamma passing rates and DVH values. The novel GDSAmean metric was developed by Steers et al. to quantify changes in the PTV mean dose (Dmean) for VMAT patients. The aim of this work is to apply the GDSA retrospectively on head‐and‐neck cancer patients treated on the newly acquired Varian Halcyon, to assess changes in GDSAmean, and to evaluate the cause of day‐to‐day changes in the time‐plot series. In‐vivo EPID transmission images of head‐and‐neck cancer patients treated between August 2019 and July 2020 were analyzed retrospectively. The GDSAmean was determined for all patients treated. The changes in patient anatomy and rotational errors were quantified using the daily CBCT images and added to a time‐plot with the daily change in GDSAmean. Over 97% of the delivered treatment fractions had a GDSAmean < 3%. Thirteen of the patients received at least one treatment fraction where the GDSAmean > 3%. Most of these deviations occurred for the later fractions of radiotherapy treatment. Additionally, 92% of these patients were treated for malignancies involving the larynx and oropharynx. Notable deviations in the effective separation diameters were observed for 62% of the patients where the change in GDSAmean > 3%. For the other five cases with GDSAmean < 3%, the mean pitch, roll, and yaw rotational errors were 0.90°, 0.45°, and 0.43°, respectively. A GDSAmean > 3% was more likely due to a change in separation, whereas a GDSAmean < 3% was likely caused by rotational errors. Pitch errors were shown to be the most dominant. The GDSAmean is easily implementable and can aid in scheduling new CT scans for patients before significant deviations in dose delivery occur.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.