Purpose This paper studies spatial resolution that is achievable with a fast slot‐scanning tomosynthesis approach for orthopedic examinations. Hereby, we use parallel scanning motion implemented in a twin robotic x‐ray system. Methods We have measured and analyzed the modulation transfer function (MTF) for various combinations of scanning speed, x‐ray tube voltage, pulse length, the nominal focal spot size as well as source‐to‐object distances. Moreover, we present a theoretical model which describes the system in terms of the MTF. The system was equipped with newly developed linear trajectory prototypes for slot scanning. The acquired images form the basis for a small‐angle tomosynthesis reconstruction. In total, three different scanning speeds (27, 14, 8 cm/s), pulse lengths (1, 2, 4 ms), tube voltages (80, 100, 120 kV), two nominal focal spot sizes (0.6, 1.0), and three source‐to‐object distances (950, 1050, 1150 mm) were investigated. To determine the resolution capabilities, we measured the MTF for the given parameter space. The results were then used to design a filter that yields a desired resolution in the reconstructed image. In addition, we also measured the noise power spectrum (NPS) to show the influence of the aforementioned filters on the noise distribution. Results We have shown that the presented model is in good agreement with the performed measurements. Scanning speed and pulse width have an impact on the MTF in the scanning direction. Up to a travel distance of 0.3 mm during an x‐ray pulse, an isotropic resolution can be achieved. Longer pulse width or higher scanning speed cause anisotropic resolution. Moreover, it is shown that none of the investigated parameters have an influence on the MTF perpendicular to the scanning direction (slot direction). The 10% MTF value ranges between 9 and 18 lp/cm in the scanning direction and about 18 lp/cm in slot direction. Tube voltage, nominal focal spot size as well as the source‐to‐object distance showed no major impact on the system MTF. In terms of the anisotropic resolution capabilities, we have shown that limiting the resolution in the slot direction to obtain isotropic resolution is possible yet at the cost of an inhomogeneous noise pattern. However, maintaining the resolution in slot direction will provide a better edge response and a more homogeneous noise texture at the cost of an inhomogeneous image resolution. Conclusions We have demonstrated the feasibility of the slot‐scanning technique using a twin‐robotic x‐ray system. Even the fastest scanning mode (27 cm/s) yields image resolution on a level that is sufficient for typical orthopedic examinations in terms of musculoskeletal (MSK) measurements. Moreover, it could be shown that the application of specifically designed target MTFs on two‐dimensional x‐ray images is feasible.
Photoplethysmography (PPG) is a non-invasive, inexpensive and unobtrusive method to achieve heart rate monitoring during physical exercises. Motion artifacts during exercise challenge the heart rate estimation from wrist-type PPG signals. This paper presents a methodology to overcome these limitation by incorporating acceleration information. The proposed algorithm consisted of four stages: (1) A wavelet based denoising, (2) an acceleration based denoising, (3) a frequency based approach to estimate the heart rate followed by (4) a postprocessing step. Experiments with different movement types such as running and rehabilitation exercises were used for algorithm design and development. Evaluation of our heart rate estimation showed that a mean absolute error 1.96 bpm (beats per minute) with standard deviation of 2.86 bpm and a correlation of 0.98 was achieved with our method. These findings suggest that the proposed methodology is robust to motion artifacts and is therefore applicable for heart rate monitoring during sports and rehabilitation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.