Our observations indicate that cardiac damage from TKI treatment is a largely underestimated phenomenon but is manageable if patients have careful cardiovascular monitoring and cardiac treatment at the first signs of myocardial damage.
The use of intermittent coronary sinus occlusion and intermittent coronary sinus occlusion in combination with retroperfusion of arterial blood significantly decreases ischemic damage during coronary occlusions. Intermittent coronary sinus occlusion in combination with retroperfusion exhibits no significant profit in salvaging the ischemic myocardium in comparison with that provided by intermittent coronary sinus occlusion alone.
Background
Transcatheter tricuspid valve intervention became an option for pacemaker lead-associated tricuspid regurgitation. This study investigated the progression of tricuspid regurgitation (TR) in patients with or without pre-existing right ventricular dilatation (RVD) undergoing pacemaker implantation.
Methods
Patients were included if they had implantation of transtricuspid pacemaker lead and completed echocardiography before and after implantation. The cohort was divided in patients with and without RVD (cut-off basal RV diameter ≥ 42 mm). TR was graded in none/mild, moderate, and severe. Worsening of one grade was defined as progression. Survival analyses were plotted for 10 years.
Results
In total, 990 patients were analyzed (24.5% with RVD). Progression of TR occurred in 46.1% of patients with RVD and in 25.6% of patients without RVD (P < 0.001). Predictors for TR progression were RV dilatation (OR 2.04; 95% CI 1.27–3.29; P = 0.003), pre-existing TR (OR 4.30; 95% CI 2.51–7.38; P < 0.001), female sex (OR 1.68; 95% CI 1.16–2.43; P = 0.006), single RV lead (OR 1.67; 95% CI 1.09–2.56; P = 0.018), mitral regurgitation (OR 2.08; 95% CI 1.42–3.05; P < 0.001), and enlarged left atrium (OR 1.98; 95% CI 1.07–3.67; P = 0.03). Survival-predictors were pacemaker lead-associated TR (HR 1.38; 95% CI 1.04–1.84; P = 0.028), mitral regurgitation (HR 1.34; 95% CI 1.02–1.77; P = 0.034), heart failure (HR 1.75; 95% CI 1.31–2.33; P < 0.001), kidney disease (HR 1.62; 95% CI 1.25–2.11; P < 0.001), and age ≥ 80 years (HR 2.84; 95% CI 2.17–3.71; P < 0.001).
Conclusions
Patients with RVD receiving pacemaker suffered from increased TR progression, leading to decreased survival.
Graphic abstract
Background: The implantation of rapid-deployment aortic valves may interfere with the conduction system of the heart. This study evaluates the occurrence and predictive factors of conduction anomalies in patients undergoing surgical aortic valve replacement (SAVR) with a rapid-deployment balloon-expandable bioprosthesis in a single-center, real-world experience.Methods: Between May 2010 and April 2019, 700 consecutive patients were included in a prospective, ongoing database with a longitudinal follow-up preoperatively, at discharge, and at 3 months, 1 year, 3 years, and 5 years postoperatively. Thirty-seven patients (5.3%) had a permanent pacemaker at baseline and were excluded from further analysis, leaving 663 patients for analysis. Assessment of conduction anomalies was performed by electrocardiography (ECG) monitoring and repeated 12-lead ECG during the hospital stay and at postoperative follow-ups.Results: Preoperatively, 126 patients (19.0%) presented with different conduction disturbances. New permanent pacemaker implantation (PPI) occurred in 61 patients during the first 14 days (cumulative incidence, 9.4%). The indication for PPI was complete atrioventricular block in 47 cases (77%). Preoperative conduction anomalies, such as right bundle branch block, as well as operative characteristics (concomitant procedures) were found to be independent predictors for new PPI. One-year survival was 98% in patients with new early PPI and 96% in those without new early PPI (P ¼ .60).
Conclusions:The PPI rate was in the range of previous reports for rapiddeployment prostheses. PPI did not have a significant influence on short-to intermediate-term survival. Case selection with exclusion of patients presenting with baseline conduction disturbances may decrease the rate of new PPIs after SAVR with rapid-deployment balloon-expandable bioprostheses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.