This paper provides a review of the space-time (ST) and Arbitrary Lagrangian-Eulerian (ALE) techniques developed by the first three authors' research teams for patientspecific cardiovascular fluid mechanics modeling, including fluid-structure interaction (FSI). The core methods are the ALE-based variational multiscale (ALE-VMS) method, the Deforming-Spatial-Domain/Stabilized ST formulation, and the stabilized ST FSI 2437 Math. Models Methods Appl. Sci. 2014.24:2437-2486. Downloaded from www.worldscientific.com by UNIVERSITY OF GEORGIA on 11/27/14. For personal use only. 2438 K. Takizawa et al.technique. A good number of special techniques targeting cardiovascular fluid mechanics have been developed to be used with the core methods. These include: (i) arterial-surface extraction and boundary condition techniques, (ii) techniques for using variable arterial wall thickness, (iii) methods for calculating an estimated zero-pressure arterial geometry, (iv) techniques for prestressing of the blood vessel wall, (v) mesh generation techniques for building layers of refined fluid mechanics mesh near the arterial walls, (vi) a special mapping technique for specifying the velocity profile at an inflow boundary with noncircular shape, (vii) a scaling technique for specifying a more realistic volumetric flow rate, (viii) techniques for the projection of fluid-structure interface stresses, (ix) a recipe for pre-FSI computations that improve the convergence of the FSI computations, (x) the Sequentially-Coupled Arterial FSI technique and its multiscale versions, (xi) techniques for calculation of the wall shear stress (WSS) and oscillatory shear index (OSI), (xii) methods for stent modeling and mesh generation, (xiii) methods for calculation of the particle residence time, and (xiv) methods for an estimated element-based zero-stress state for the artery. Here we provide an overview of the special techniques for WSS and OSI calculations, stent modeling and mesh generation, and calculation of the residence time with application to pulsatile ventricular assist device (PVAD). We provide references for some of the other special techniques. With results from earlier computations, we show how these core and special techniques work.
Ventricular assist devices (VADs) provide mechanical circulatory support to offload the work of one or both ventricles during heart failure. They are used in the clinical setting as destination therapy, as bridge to transplant, or more recently as bridge to recovery to allow for myocardial remodeling. Recent developments in computational simulation allow for detailed assessment of VAD hemodynamics for device design and optimization for both children and adults. Here, we provide a focused review of the recent literature on finite element methods and optimization for VAD simulations. As VAD designs typically fall into two categories, pulsatile and continuous flow devices, we separately address computational challenges of both types of designs, and the interaction with the circulatory system with three representative case studies. In particular, we focus on recent advancements in finite element methodology that has increased the fidelity of VAD simulations. We outline key challenges, which extend to the incorporation of biological response such as thrombosis and hemolysis, as well as shape optimization methods and challenges in computational methodology.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.