BackgroundPrevious studies have reported that walking cadence (steps/min) is associated with absolutely-defined intensity (metabolic equivalents; METs), such that cadence-based thresholds could serve as reasonable proxy values for ambulatory intensities.PurposeTo establish definitive heuristic (i.e., evidence-based, practical, rounded) thresholds linking cadence with absolutely-defined moderate (3 METs) and vigorous (6 METs) intensity.MethodsIn this laboratory-based cross-sectional study, 76 healthy adults (10 men and 10 women representing each 5-year age-group category between 21 and 40 years, BMI = 24.8 ± 3.4 kg/m2) performed a series of 5-min treadmill bouts separated by 2-min rests. Bouts began at 0.5 mph and increased in 0.5 mph increments until participants: 1) chose to run, 2) achieved 75% of their predicted maximum heart rate, or 3) reported a Borg rating of perceived exertion > 13. Cadence was hand-tallied, and intensity (METs) was measured using a portable indirect calorimeter. Optimal cadence thresholds for moderate and vigorous ambulatory intensities were identified using a segmented regression model with random coefficients, as well as Receiver Operating Characteristic (ROC) models. Positive predictive values (PPV) of candidate heuristic thresholds were assessed to determine final heuristic values.ResultsOptimal cadence thresholds for 3 METs and 6 METs were 102 and 129 steps/min, respectively, using the regression model, and 96 and 120 steps/min, respectively, using ROC models. Heuristic values were set at 100 steps/min (PPV of 91.4%), and 130 steps/min (PPV of 70.7%), respectively.ConclusionsCadence thresholds of 100 and 130 steps/min can serve as reasonable heuristic thresholds representative of absolutely-defined moderate and vigorous ambulatory intensity, respectively, in 21–40 year olds. These values represent useful proxy values for recommending and modulating the intensity of ambulatory behavior and/or as measurement thresholds for processing accelerometer data.Trial registrationClinicaltrials.gov (NCT02650258).Electronic supplementary materialThe online version of this article (10.1186/s12966-019-0769-6) contains supplementary material, which is available to authorized users.
Background In younger adults (i.e., those < 40 years of age) a walking cadence of 100 steps/min is a consistently supported threshold indicative of absolutely-defined moderate intensity ambulation (i.e., ≥ 3 metabolic equivalents; METs). Less is known about the cadence-intensity relationship in adults of middle-age. Purpose To establish heuristic (i.e., evidence-based, practical, rounded) cadence thresholds for absolutely-defined moderate (3 METs) and vigorous (6 METs) intensity in adults 41 to 60 years of age. Methods In this cross-sectional study, 80 healthy adults of middle-age (10 men and 10 women representing each 5-year age-group between 41 to 60 years; body mass index = 26.0 ± 4.0 kg/m2) walked on a treadmill for 5-min bouts beginning at 0.5 mph and increasing in 0.5 mph increments. Performance termination criteria included: 1) transitioning to running, 2) reaching 75% of age-predicted maximum heart rate, or 3) reporting a Borg rating of perceived exertion > 13. Cadence was directly observed (i.e., hand tallied). Intensity (i.e., oxygen uptake [VO2] mL/kg/min) was assessed with an indirect calorimeter and converted to METs (1 MET = 3.5 mL/kg/min). A combination of segmented regression and Receiver Operating Characteristic (ROC) modeling approaches was used to identify optimal cadence thresholds. Final heuristic thresholds were determined based on an evaluation of classification accuracy (sensitivity, specificity, positive and negative predictive value, overall accuracy). Results The regression model identified 101.7 (95% Predictive Interval [PI]: 54.9–110.6) and 132.1 (95% PI: 122.0–142.2) steps/min as optimal cadence thresholds for 3 METs and 6 METs, respectively. Corresponding values based on ROC models were 98.5 (95% Confidence Intervals [CI]: 97.1–104.9) and 117.3 (95% CI: 113.1–126.1) steps/min. Considering both modeling approaches, the selected heuristic thresholds for moderate and vigorous intensity were 100 and 130 steps/min, respectively. Conclusions Consistent with our previous report in 21 to 40-year-old adults, cadence thresholds of 100 and 130 steps/min emerged as heuristic values associated with 3 and 6 METs, respectively, in 41 to 60-year-old adults. These values were selected based on their utility for public health messaging and on the trade-offs in classification accuracy parameters from both statistical methods. Findings will need to be confirmed in older adults and in free-living settings.
Background Heuristic (i.e., evidence-based, rounded) cadences of ≥100 and ≥ 130 steps/min have consistently corresponded with absolutely-defined moderate (3 metabolic equivalents [METs]) and vigorous (6 METs) physical activity intensity, respectively, in adults 21–60 years of age. There is no consensus regarding similar thresholds in older adults. Purpose To provide heuristic cadence thresholds for 3, 4, 5, and 6 METs in 61–85-year-old adults. Methods Ninety-eight community-dwelling ambulatory and ostensibly healthy older adults (age = 72.6 ± 6.9 years; 49% women) walked on a treadmill for a series of 5-min bouts (beginning at 0.5 mph with 0.5 mph increments) in this laboratory-based cross-sectional study until: 1) transitioning to running, 2) reaching ≥75% of their age-predicted maximum heart rate, or 3) reporting a Borg rating of perceived exertion > 13. Cadence was directly observed and hand-tallied. Intensity (oxygen uptake [VO2] mL/kg/min) was assessed with indirect calorimetry and converted to METs (1 MET = 3.5 mL/kg/min). Cadence thresholds were identified via segmented mixed effects model regression and using Receiver Operating Characteristic (ROC) curves. Final heuristic cadence thresholds represented an analytical compromise based on classification accuracy (sensitivity, specificity, positive and negative predictive value, and overall accuracy). Results Cadences of 103.1 (95% Prediction Interval: 70.0–114.2), 116.4 (105.3–127.4), 129.6 (118.6–140.7), and 142.9 steps/min (131.8–148.4) were identified for 3, 4, 5, and 6 METs, respectively, based on the segmented regression. Comparable values based on ROC analysis were 100.3 (95% Confidence Intervals: 95.7–103.1), 111.5 (106.1–112.9), 116.0 (112.4–120.2), and 128.6 steps/min (128.3–136.4). Heuristic cadence thresholds of 100, 110, and 120 were associated with 3, 4, and 5 METs. Data to inform a threshold for ≥6 METs was limited, as only 6/98 (6.0%) participants achieved this intensity. Conclusions Consistent with previous data collected from 21–40 and 41–60-year-old adults, heuristic cadence thresholds of 100, 110, and 120 steps/min were associated with 3, 4, and 5 METs, respectively, in 61–85-year-old adults. Most older adults tested did not achieve the intensity of ≥6 METs; therefore, our data do not support establishing thresholds corresponding with this intensity level. Trial registration Clinicaltrials.gov NCT02650258. Registered 24 December 2015.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers