Study Design.
A retrospective cohort study at a single institution.
Objective.
The aim of this study was to analyze the perioperative and postoperative outcomes of patients who underwent open transforaminal lumbar interbody fusion (O-TLIF) and bilateral minimally invasive surgery (MIS) Wiltse approach TLIF (Wil-TLIF).
Summary of Background Data.
Several studies have compared open TLIF to MIS TLIF; however, comparing the techniques using a large cohort of one-level TLIFs has not been fully explored.
Methods.
We reviewed the charts of patients undergoing a single-level primary posterior lumbar interbody fusion between 2012 and 2017. The cases were categorized as Open TLIF (traditional midline exposure including lateral exposure of transverse processes) or bilateral paramedian Wiltse TLIF approach. Differences between groups were assessed by t tests.
Results.
Two hundred twenty-seven patients underwent one-level primary TLIF (116 O-TLIF, 111 Wil-TLIF). There was no difference in age, gender, American Society of Anesthesiologists (ASA), or body mass index (BMI) between groups. Wil-TLIF had the lowest estimated blood loss (EBL; 197 vs. 499 mL O-TLIF, P ≤ 0.001), length of stay (LOS; 2.7 vs. 3.6 days O-TLIF, P ≤ 0.001), overall complication rate (12% vs. 24% O-TLIF, P = 0.015), minor complication rate (7% vs. 16% O-TLIF, P = 0.049), and 90-day readmission rate (1% vs. 8% O-TLIF, P = 0.012). Wil-TLIF was associated with the higher fluoroscopy time (83 vs. 24 seconds O-TLIF, P ≤ 0.001). There was not a significant difference in operative time, intraoperative or neurological complications, extubation time, reoperation rate, or infection rate.
Conclusion.
In comparing Wiltse MIS TLIF to Open TLIF, the minimally invasive paramedian Wiltse approach demonstrated the lowest EBL, LOS, readmission rates, and complications, but longer fluoroscopy times when compared with the traditional open approach.
Level of Evidence: 3
Study Design: Retrospective clinical review. Objective: To assess the use of intraoperative computed tomography (CT) image-guided navigation (IGN) and robotic assistance in posterior lumbar surgery and their relationship with patient radiation exposure and perioperative outcomes. Methods: Patients ≥18 years old undergoing 1- to 2-level transforaminal lateral interbody fusion in 12-month period were included. Chart review was performed for pre- and intraoperative data on radiation dose and perioperative outcomes. All radiation doses are quantified in milliGrays (mGy). Univariate analysis and multivariate logistic regression analysis were utilized for categorical variables. One-way analysis of variance with post hoc Tukey test was used for continuous variables. Results: A total of 165 patients were assessed: 12 IGN, 62 robotic, 56 open, 35 fluoroscopically guided minimally invasive surgery (MIS). There was a lower proportion of women in open and MIS groups ( P = .010). There were more younger patients in the MIS group ( P < .001). MIS group had the lowest mean posterior levels fused ( P = .015). Total-procedure radiation, total-procedure radiation/level fused, and intraoperative radiation was the lowest in the open group and highest in the MIS group compared with IGN and robotic groups (all P < .001). Higher proportion of robotic and lower proportion of MIS patients had preoperative CT ( P < .001). Estimated blood loss ( P = .002) and hospital length of stay ( P = .039) were lowest in the MIS group. Highest operative time was observed for IGN patients ( P < .001). No differences were observed in body mass index, Charlson Comorbidity Index, and postoperative complications ( P = .313, .051, and .644, respectively). Conclusion: IGN and robotic assistance in posterior lumbar fusion were associated with higher intraoperative and total-procedure radiation exposure than open cases without IGN/robotics, but significantly less than MIS without IGN/robotics, without differences in perioperative outcomes. Fluoro-MIS procedures reported highest radiation exposure to patient, and of equal concern is that the proportion of total radiation dose also applied to the surgeon and operating room staff in fluoro-MIS group is higher than in IGN/robotics and open groups.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.