ObjectiveTo document the causes of high signal intensity of the meniscus which is not caused by definite meniscal tears on MR imaging, through correlation with histological examination.Materials and MethodsFor the correlation between the MR image and histology, we obtained prospectively 31 meniscal specimens from 21 patients. Proton density-weighted turbo spin-echo MR images were used. Minimal tear, thinning of the lamellar layer, degeneration of the central layer, and radial tie fibers were detected upon histological examination, and were correlated with the corresponding MR images.ResultsMinimal tear of the lamellar layer was seen in 60 zones out of 100 slides. On MR images, 29 (48.3%) of these 60 zones had high signal intensity. Thinning of the lamellar layer was seen in 24 zones, with 7 (29.2%) having high signal intensity. 57 central zones showed degenerative change in the central layer and high signal intensity on all corresponding MR images. Radial tie fibers in the central layer appeared as high signal intensity areas.ConclusionMinimal tear and thinning of the lamellar layer, degeneration and radial tie fibers of the central layer of the meniscus cause high signal intensity on MR images.
ObjectiveTo compare phase-inversion sonography during the liver-specific phase of contrast enhancement using a microbubble contrast agent with conventional B-mode sonography for the detection of VX2 liver tumors.Materials and MethodsTwenty-three rabbits, 18 of which had VX2 liver tumor implants, received a bolus injection of 0.6 g of Levovist (200 mg/ml). During the liver-specific phase of this agent, they were evaluated using both conventional sonography and contrast-enhanced phase-inversion harmonic imaging (CE-PIHI). Following sacrifice of the animals, pathologic analysis was performed and the reference standard thus obtained. The conspicuity, size and number of the tumors before and after contrast administration, as determined by a sonographer, were compared between the two modes and with the pathologic findings.ResultsCE-PIHI demonstrated marked hepatic parenchymal enhancement in all rabbits. For VX2 tumors detected at both conventional US and CE- PIHI, conspicuity was improved by contrast-enhanced PIHI. On examination of gross specimens, 52 VX2 tumors were identified. Conventional US correctly detected 18 of the 52 (34.6%), while PIHI detected 35 (67.3%) (p < 0.05). In particular, conventional US detected only three (8.3%) of the 36 tumors less than 10 mm in diameter, but CE-PIHI detected 19 such tumors (52.8%) (p < 0.05).ConclusionCompared to conventional sonography, PIHI performed during the liver-specific phase after intravenous injection of Levovist is markedly better at detecting VX2 liver tumors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.