ObjectiveA general orientation along the cervical spine could be estimated by external landmarks, and it was useful, quick and less exposable to radiation, but, sometimes it gave reference confusion of target cervical level. The authors reviewed the corresponding between the neck external landmarks and cervical levels.MethodsTotally 1,031 cervical lateral radiographs of different patients were reviewed in single university hospital. Its compositions were 534 of males and 497 females; 86 of second decades (10-19 years-old), 169 of third decades, 159 of fourth decades, 209 of fifth decades, 275 of sixth decades, and 133 of more than seventh decades (>60 years-old). Reference external landmarks (mandible, hyoid bone, thyroid cartilage, and cricothyroid membrane) with compounding factors were reviewed.ResultsThe reference levels of cervical landmarks were C2.13 with mandible angle, C3.54 with hyoid bone, C5.12 with thyroid cartilage, and C6.01 with cricothyroid membrane. The reference levels of cervical landmarks were differently observed by sex, age, and somatometric measurement (height) accordingly mandible angle from C1 to C3, hyoid bone from disc level of C2 and C3 to C5, thyroid cartilage from disc level of C3 and C4 to C7, and cricothyroid membrane from C4 to disc level of C7 and T1.ConclusionSurface landmarks only provide general reference points, but not correspond to exact levels of the cervical spine. Intraoperative fluoroscopy ensures a more precise placement to the targeted cervical level.
This case report involves tracheal intubation using i-gel® in combination with a lightwand in a patient with a difficult airway, classified as Cormack-Lehane grade 3. I-gel® was used during anesthesia induction to properly maintain ventilation. The authors have previously reported successful tracheal intubation on a patient with a difficult airway through the use of i-gel® and a fiberoptic bronchoscope. However, if the use of a fiberoptic bronchoscope is not immediately available in a patient with a difficult airway, tracheal intubation may be performed by using i-gel® and a lightwand in a patient with difficult airway, allowing the safe induction of anesthesia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.