Summary Intubation with a double‐lumen tube is important for achieving one‐lung ventilation and facilitating thoracic surgery. The GlideScope® videolaryngoscope (Verathon Inc., Bothell, WA, USA) is designed to assist tracheal intubation for patients with a difficult airway. We wished to compare the GlideScope and direct laryngoscopy for double‐lumen tube intubation. Sixty adult patients requiring a double‐lumen tube for thoracic surgery and predicted uncomplicated laryngoscopy were randomly assigned to a direct Macintosh laryngoscopy group (n = 30) or a GlideScope group (n = 30). The mean (SD) duration of intubation was longer in the Macintosh group (62.5 (29.7) s) than in the GlideScope group (45.6 (10.7) s; p = 0.007). There was no difference in the success of the first attempt at intubation (26/30 (87%) and 30/30 (100%) for Macintosh and GlideScope groups, respectively; p = 0.112). The incidence of sore throat and hoarseness was higher in the Macintosh group (18 (60%) and 14 (47%), respectively) than in the GlideScope group (6 (20%) and 4 (13%), respectively; p = 0.003 and 0.004). We conclude that double‐lumen tube intubation in patients with predicted normal laryngoscopy is easier using the GlideScope videolaryngoscope than the Macintosh laryngoscope.
With the increase in the number of automobile accidents, traumatic tricuspid insufficiency, a rare complication of non-penetrating blunt chest injury, has become an important problem. This kind of injury has been found more frequently during the last decade, partly because of better diagnostic procedures and a better understanding of the pathology. Here, we report a 22-year-old male patient who suffered chest trauma from an automobile accident. Echocardiography demonstrated tricuspid chordae tendinae rupture with remarkable tricuspid regurgitation. We discuss this case in comparison with the previous literature. This case reminds us that physicians in the emergency department should be aware of this potential complication following non-penetrating chest trauma.
BackgroundThe use of a video-assisted laryngoscope (VL) has been shown to reduce the time to achieve intubation with a double-lumen endobronchial tube (DLT). As the blade of the VL is curved differently to a standard laryngoscope, the DLT must be angled into a hockey stick shape to fit properly. We conducted a study to establish which direction of angulation was best to facilitate correct positioning of the DLT when using a VL.MethodsWe enrolled patients scheduled for thoracic surgery who required intubation with a DLT. They were prospectively randomized into one of two groups: those intubated with a DLT angled to conceal the tracheal orifice (the tracheal orifice-covered, TOC) group or the tracheal orifice-exposed (TOE) group. The composite primary outcome measures were time taken to intubate and the frequency of first-time success. The time taken to intubate was divided into: T1, the time from mouth opening to visualization of the vocal cords with the VL; and T2, the time taken to advance the DLT through the cords until its tip lay within the trachea and three carbon dioxide waveforms had been detected by capnography. The hemodynamic responses to intubation and intubation-related adverse events were also recorded.ResultsSixty-six patients completed the study, with 33 in each group. Total intubation time was significantly shorter in the TOC group (mean 30.6 ± standard deviation 2.7 seconds versus 38.7 ± 3.3 seconds, p <0.0001). T2 was also significantly shorter in the TOC group than the TOE group (27.2 ± 2.5 seconds versus 34.9 ± 3.0 seconds, p <0.0001). The severity of hoarseness on the first postoperative day and sore throat on the fourth postoperative day were significantly lower in the TOC group than the TOE group (p = 0.02 and <0.0001, respectively). The hemodynamic responses to intubation were broadly similar between the groups.ConclusionWhen placing a left-sided DLT using a VL, angling the bronchial lumen to a hockey stick shape that conceals the tracheal lumen saves time and ameliorates the severity of post-intubation complications.Trial registrationClinicalTrials.gov Identifier: NCT01605591.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.