PurposeAs computed tomography (CT) imaging is the most commonly used modality for treatment planning in radiation therapy, metal artifacts in the planning CT images may complicate the target delineation and reduce the dose calculation accuracy. Although current CT scanners do provide certain correction steps, it is a common understanding that there is not a universal solution yet to the metal artifact reduction (MAR) in general. Particularly noting the importance of MAR for radiation treatment planning, we propose a novel MAR method in this work that recruits an additional tilted CT scan and synthesizes nearly metal‐artifact‐free CT images.MethodsThe proposed method is based on the facts that the most pronounced metal artifacts in CT images show up along the x‐ray beam direction traversing multiple metallic objects and that a tilted CT scan can provide complementary information free of such metal artifacts in the earlier scan. Although the tilted CT scan would contain its own metal artifacts in the images, the artifacts may manifest in a different fashion leaving a chance to concatenate the two CT images with the metal artifacts much suppressed. We developed an image processing technique that uses the structural similarity (SSIM) for suppressing the metal artifacts. On top of the additional scan, we proposed to use an existing MAR method for each scan if necessary to further suppress the metal artifacts.ResultsThe proposed method was validated by a simulation study using the pelvic region of an XCAT numerical phantom and also by an experimental study using the head part of the Rando phantom. The proposed method was found to effectively reduce the metal artifacts. Quantitative analyses revealed that the proposed method reduced the mean absolute percentages of the error by up to 86% and 89% in the simulation and experimental studies, respectively.ConclusionsIt was confirmed that the proposed method, using complementary information acquired from an additional tilted CT scan, can provide nearly metal‐artifact‐free images for the treatment planning.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.