Background: Various technologies have been developed to quantify the pivot shift, as it is regarded as a key indicator of anterolateral rotatory laxity of the knee. Purpose: To determine the usefulness of a commercially available triaxial accelerometer (Kinematic Rapid Assessment [KiRA]) in numerically quantifying the pivot shift in patients under anesthesia with an anterior cruciate ligament (ACL)–deficient knee. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: Both knees of 50 patients (26 male [mean age, 30.4 years], 24 female [mean age, 26.6 years]) under anesthesia were assessed immediately before unilateral ACL reconstruction by an orthopaedic fellow and 1 of 3 experienced knee surgeons. The pivot-shift grade and 2 KiRA outputs (range of acceleration and slope of acceleration change) were compared. Results: The surgeon and fellow recorded the same pivot-shift grade for 45 of 50 patients (90%). Data from the 5 patients with no agreement and 1 patient with extreme outlying data were excluded from subsequent analysis. Using the KiRA range and slope data, the surgeon identified the injured knee in 74% and 76% of patients, respectively, while the fellow’s rate of injured knee identification was 74% and 80%, respectively. A correlation could be found only between pivot-shift grade and surgeon-derived range data ( ρ = 0.40; P < .01) but not slope data or any fellow-derived outputs. Using the surgeon-derived range data, there was a significant difference between a grade 3 pivot (>5 m/s2) and a grade 1 or 2 pivot (<5 m/s2) ( P = .01). Conclusion: Although a correlation between KiRA output data and pivot-shift grade was found when the device was used by an experienced surgeon, there was no correlation when used by a well-trained but less experienced orthopaedic fellow. Furthermore, the KiRA output data identified the ACL-deficient knee correctly in only 74% of patients. Although a threshold acceleration range value could be identified, above which the value was associated with a grade 3 pivot shift, this was dependent on the examiner, and distinction between other grades could not be made.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.