Reactor pressure vessel (RPV) dose assessments for UK PWR plant have been performed using the AEA Technology Monte Carlo radiation transport code MCBEND. Monte Carlo models of the plant are validated against fast neutron activation measurements performed on flux monitor wires from surveillance capsules removed at the end of each cycle. These monitors have a range of time and spectrum dependencies. A computationally efficient method has been developed that calculates dosimeter activation values in a single calculation per reaction. This utilizes MCBEND's advanced acceleration techniques as well as an innovative treatment of neutron source data. The method employs plant validated, three-dimensionsal (3D) time-dependent neutron source data obtained from the UK reactor physics code PANTHER. Mean ratios of calculation (C) to experiment (E) obtained for the surveillance capsules removed to date are 1.02, 0.99 and 1.04. RPV dose distributions in axial, azimuthal and radial detail are obtained with a single calculation per reactor octant. Normalization to mean C/E provides best estimate dose data for the RPV inner surface and quarter thickness. A similar calculation provides dose data for the RPV top weld.
This paper describes the calculation of the attenuation of neutron dose through the steel pressure vessels of Magnox power plant operated by BNFL, Magnox Generation Division. These data are required for the assessment of the structural integrity of the plant. Detailed three-dimensional neutron transport models of the reactors, pressure vessels and surrounding bioshields have been developed using the AEA Technology Monte-Carlo code MCBEND. These have been used to calculate neutron fluxes through the pressure vessel in both sub-core and side-core regions of pressure vessels, the two bounding extremes of the incident neutron spectra. The effect of postulated cracks in the RPV is shown not to influence the predicted neutron doses. A comparison with neutron fluxes measured from through wall samples removed from a decommissioned reactor show the calculation route to be accurate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.