Purpose Prostate cancer is the most common non‐cutaneous cancer among men in the United States and is the second leading cause of cancer death in American men. (Siegel et al. [2019] CA: A Cancer J Clin.69(1):7‐34.) Focal laser ablation (FLA) has the potential to control small tumors while preserving urinary and erectile function by leaving the neurovascular bundles and urethral sphincters intact. Accurate needle guidance is critical to the success of FLA. Multiparametric magnetic resonance images (mpMRI) can be used to identify targets, guide needles, and assess treatment outcomes. The purpose of this work was to design and evaluate the accuracy of an MR‐compatible mechatronic system for in‐bore transperineal guidance of FLA ablation needles to localized lesions in the prostate. Methods The mechatronic system was constructed entirely of non‐ferromagnetic materials, with actuation controlled by piezoelectric motors and optical encoders. The needle guide hangs between independent front and rear two‐link arms, which allows for horizontal and vertical translation as well as pitch and yaw rotation of the guide with a 6.0 cm range of motion in each direction. Needles are inserted manually through a chosen hole in the guide, which has been aligned with the target in the prostate. Open‐air positioning error was evaluated using an optical tracking system (0.25 mm RMS accuracy) to measure 125 trajectories in free space. Correction of systematic bias in the system was performed using 85 of the trajectories, and the remaining 40 were used to estimate the residual error. The error was calculated as the horizontal and vertical displacement between the axis of the desired and measured trajectories at a typical needle insertion depth of 10 cm. MR‐compatibility was evaluated using a grid phantom to assess image degradation due to the presence of the system, and induced force, heating, and electrical interference in the system were assessed qualitatively. In‐bore positioning error was evaluated on 25 trajectories. Results Open‐air mean positioning error at the needle tip was 0.80 ± 0.36 mm with a one‐sided 95% confidence interval of 1.40 mm. The mean deviation of needle trajectories from the planned direction was 0.14 ± 0.06∘. In the MR bore, the mean positioning error at the needle tip was 2.11 ± 1.05 mm with a one‐sided 95% prediction interval of 3.84 mm. The mean angular error was 0.49 ± 0.26∘. The system was found to be compatible with the MR environment under the specified gradient‐echo sequence parameters used in this study. Conclusion A complete system for delivering needles to localized prostate tumors was developed and described in this work, and its compatibility with the MR environment was demonstrated. In‐bore MRI positioning error was sufficiently small for targeting small localized prostate tumors.
Background Mammographic screening has reduced mortality in women through the early detection of breast cancer. However, the sensitivity for breast cancer detection is significantly reduced in women with dense breasts, in addition to being an independent risk factor. Ultrasound (US) has been proven effective in detecting small, early‐stage, and invasive cancers in women with dense breasts. Purpose To develop an alternative, versatile, and cost‐effective spatially tracked three‐dimensional (3D) US system for whole‐breast imaging. This paper describes the design, development, and validation of the spatially tracked 3DUS system, including its components for spatial tracking, multi‐image registration and fusion, feasibility for whole‐breast 3DUS imaging and multi‐planar visualization in tissue‐mimicking phantoms, and a proof‐of‐concept healthy volunteer study. Methods The spatially tracked 3DUS system contains (a) a six‐axis manipulator and counterbalanced stabilizer, (b) an in‐house quick‐release 3DUS scanner, adaptable to any commercially available US system, and removable, allowing for handheld 3DUS acquisition and two‐dimensional US imaging, and (c) custom software for 3D tracking, 3DUS reconstruction, visualization, and spatial‐based multi‐image registration and fusion of 3DUS images for whole‐breast imaging. Spatial tracking of the 3D position and orientation of the system and its joints (J1–6) were evaluated in a clinically accessible workspace for bedside point‐of‐care (POC) imaging. Multi‐image registration and fusion of acquired 3DUS images were assessed with a quadrants‐based protocol in tissue‐mimicking phantoms and the target registration error (TRE) was quantified. Whole‐breast 3DUS imaging and multi‐planar visualization were evaluated with a tissue‐mimicking breast phantom. Feasibility for spatially tracked whole‐breast 3DUS imaging was assessed in a proof‐of‐concept healthy male and female volunteer study. Results Mean tracking errors were 0.87 ± 0.52, 0.70 ± 0.46, 0.53 ± 0.48, 0.34 ± 0.32, 0.43 ± 0.28, and 0.78 ± 0.54 mm for joints J1–6, respectively. Lookup table (LUT) corrections minimized the error in joints J1, J2, and J5. Compound motions exercising all joints simultaneously resulted in a mean tracking error of 1.08 ± 0.88 mm (N = 20) within the overall workspace for bedside 3DUS imaging. Multi‐image registration and fusion of two acquired 3DUS images resulted in a mean TRE of 1.28 ± 0.10 mm. Whole‐breast 3DUS imaging and multi‐planar visualization in axial, sagittal, and coronal views were demonstrated with the tissue‐mimicking breast phantom. The feasibility of the whole‐breast 3DUS approach was demonstrated in healthy male and female volunteers. In the male volunteer, the high‐resolution whole‐breast 3DUS acquisition protocol was optimized without the added complexities of curvature and tissue deformations. With small post‐acquisition corrections for motion, whole‐breast 3DUS imaging was performed on the healthy female volunteer showing relevant anatomical structures and details. Conc...
Image-guided needle biopsy of small, detectable lesions is crucial for early-stage diagnosis, treatment planning, and management of breast cancer. High-resolution positron emission mammography (PEM) is a dedicated functional imaging modality that can detect breast cancer independent of breast tissue density, but anatomical context and real-time needle visualization are not yet available to guide biopsy. We propose a mechatronic guidance system integrating an ultrasound (US)-guided core-needle biopsy (CNB) with high-resolution PEM localization to improve the spatial sampling of breast lesions. This paper presents the benchtop testing and phantom studies to evaluate the accuracy of the system and its constituent components for targeted PEM-US-guided biopsy under simulated high-resolution PEM localization. Methods: A mechatronic guidance system was developed to operate with the Radialis PEM system and a conventional US system. The system includes a user-operated guidance arm and end-effector biopsy device, integrating a US transducer and CNB gun, with its needle focused on a remote center of motion (RCM). Custom software modules were developed to track, display, and guide the end-effector biopsy device. Registration of the mechatronic guidance system to a simulated PEM detector plate was performed using a landmark-based method. Testing was performed with fiducials positioned in the peripheral and central regions of the simulated detector plate and registration error was quantified. Breast phantom experiments were performed under ideal detection and localization to evaluate for bias in the end-effector biopsy device. The accuracy of the complete mechatronic guidance system to perform targeted breast biopsy was assessed using breast phantoms with simulated lesions. Three-dimensional positioning error was quantified, and principal component analysis assessed for directional trends in 3D space within 95% prediction intervals. Targeted breast biopsies with test phantoms were performed and an overall in-plane needle targeting error was quantified. Results: The mean registration errors were 0.63 mm (N = 44) and 0.73 mm (N = 72) in the peripheral and central regions of the simulated PEM detector plate, respectively. A 3D 95% prediction ellipsoid shows an error volume <2.0 mm in diameter, centered on the mean registration error. Under ideal detection and localization, targets <1.0 mm in diameter can be sampled with 95% confidence. The complete mechatronic guidance system was able to successfully spatially sample simulated breast lesions, 4 mm and 6 mm in diameter and height (N = 20) in known 3D positions in the PEM image coordinate space. The 3D positioning error was 0.85 mm (N = 20) with 0.64 mm in-plane and 0.44 mm cross-plane component errors. Targeted breast biopsies resulted in a mean in-plane needle targeting error of 1.08 mm (N = 15) allowing for targets 1.32 mm in radius to be sampled with 95% confidence. Conclusions: We demonstrated the utility of our mechatronic guidance system for targeted breast biopsy under high...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.