Background: Lung ultrasound (LUS) is a bedside tool useful to diagnose neonatal respiratory disease and to guide surfactant therapy. LUS scores have emerged as useful tool for newborn respiratory distress but is unknown if respiratory support settings may influence it. The aim of the study was to evaluate the feasibility of LUS scores evaluating lung recruitment in term newborns with respiratory distress when noninvasive respiratory it is increased.Material and Methods: Prospective study in a tertiary neonatal intensive care unit.Inclusion criteria were term neonates with respiratory distress requiring noninvasive respiratory support with nasal continuous positive airway pressure (nCPAP) within first 6 h of life with an LUS score higher than 8 were enrolled. LUS was performed three times. First LUS (LUS-1) was done in patients in nCPAP (Fabian Device) (Acutronic) (pressure of 6 cmH 2 O). Afterwards patients were placed in duo positive airway pressure (12/6 cmH 2 O), a second LUS (LUS-2) was performed immediately and a third (LUS-3) was done 2 h later on the same respiratory support. The primary outcome was to compare LUS scores in the different timelines. Second outcomes were to evaluate the level of respiratory distress and oxygenation were evaluated with SpO 2 /fraction of inspired oxygen (FiO 2 ) ratio (S/F ratio), FiO 2 ratio, respiratory rate, and blood gas analysis which were analyzed during the LUS-1 and the LUS-3.To evaluate newborn discomfort, patients were evaluated with Crying Requires oxygen Increased vital signs Expression Sleep (CRIES) scale.Results: Forty neonates were enrolled. Fifty percent were female (n = 20), median gestational age was 38 + 4 (interquartile range [IQR]: 37 + 5-39 + 4) with a median weight of 3155 g (IQR: 2637-3532). Duration of non invasive ventilation support was 72 h (IQR: 54-96). None of the patients required surfactant therapy or mechanical ventilation. LUS scores were no different between LUS-1 9 (IQR: 8.3-10) and LUS-2 9 (IQR: 8.3-10) (p = 0.675) but there were differences between LUS-1 and LUS-3 7 (IQR: 6.3-8.5) (p = 0.036). There was an improvement in the oxygen parameters, respiratory rate, and CO 2 between LUS-1 and LUS-3 (p < 0.001). There were no changes in the CRIES scale.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.