Opioids such as morphine are the cornerstone of pain treatment. The challenge of measuring the concentrations of morphine and its active metabolites in order to assess human pharmacokinetics and monitor therapeutic drugs in children requires assays with high sensitivity in small blood volumes. We developed and validated a semi-automated LC-MS/MS assay for the simultaneous quantification of morphine and its active metabolites morphine 3β-glucuronide (M3G) and morphine 6β-glucuronide (M6G) in human plasma and in dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the internal standards were the only manual steps. Morphine and its metabolites were separated on a Kinetex 2.6-μm PFP analytical column using an acetonitrile/0.1% formic acid gradient. The analytes were detected in the positive multiple reaction mode. In plasma, the assay had the following performance characteristics: range of reliable response of 0.25-1000 ng/mL (r(2) > 0.99) for morphine, 1-1,000 ng/mL (r(2) > 0.99) for M3G, and 2.5-1,000 ng/mL for M6G. In DBS, the assay had a range of reliable response of 1-1,000 ng/mL (r(2) > 0.99) for morphine and M3G, and of 2.5-1,000 ng/mL for M6G. For inter-day accuracy and precision for morphine, M3G and M6G were within 15% of the nominal values in both plasma and DBS. There was no carryover, ion suppression, or matrix interferences. The assay fulfilled all predefined acceptance criteria, and its sensitivity using DBS samples was adequate for the measurement of pediatric pharmacokinetic samples using a small blood of only 20-50 μL.
Background-Drug-eluting stents effectively reduce restenosis but may increase late thrombosis and delayed restenosis.Persistent polymer, the drug, or a combination of both could be responsible.
Preterm and term neonates often require surgical procedures and analgesia. However, our knowledge about neonatal pharmacokinetics of fentanyl, the most commonly used drug for these procedures, and its metabolites is still incomplete. To facilitate pharmacokinetic studies of fentanyl and its metabolites in neonates and other children, we developed and validated an LC-MS/MS method based on minimally invasive, low blood volume sampling. LC-MS/MS was used for the simultaneous analysis of fentanyl, despropionyl fentanyl (DPF), and norfentanyl from dried blood samples (DBS) collected on filter paper. Positive ions were monitored using multiple reaction monitoring. Since the standard matrix for measuring fentanyl blood concentrations is plasma, the assay was developed and validated in plasma, whole blood, and then DBS. Our method was able to measure clinically relevant levels of fentanyl and its metabolites. In DBS, the lower limits of quantification were 100 pg/mL for fentanyl with a range of reliable response from 0.1 to 100 ng/mL (r(2)>0.99) and 250 pg/mL for both DPF and norfentanyl with a range of reliable response from 0.25 to 100 ng/mL (r(2)>0.99). In plasma and in DBS inter-day accuracy and precisions of fentanyl met predefined acceptance criteria and also indicated comparable assay performance in both matrices.
Patients classified as S-OSA have similar rates of AREs to D-OSA patients, but increased postoperative respiratory interventions, hospital use, and 30-day all-cause mortality. These worse postoperative outcomes in S-OSA patients than D-OSA patients could reflect the lack of awareness and appropriate management of this bedside S-OSA diagnosis after PACU discharge. Multidisciplinary interventions are needed for these high-risk patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.