Table of contentsP001 - Sepsis impairs the capillary response within hypoxic capillaries and decreases erythrocyte oxygen-dependent ATP effluxR. M. Bateman, M. D. Sharpe, J. E. Jagger, C. G. EllisP002 - Lower serum immunoglobulin G2 level does not predispose to severe flu.J. Solé-Violán, M. López-Rodríguez, E. Herrera-Ramos, J. Ruíz-Hernández, L. Borderías, J. Horcajada, N. González-Quevedo, O. Rajas, M. Briones, F. Rodríguez de Castro, C. Rodríguez GallegoP003 - Brain protective effects of intravenous immunoglobulin through inhibition of complement activation and apoptosis in a rat model of sepsisF. Esen, G. Orhun, P. Ergin Ozcan, E. Senturk, C. Ugur Yilmaz, N. Orhan, N. Arican, M. Kaya, M. Kucukerden, M. Giris, U. Akcan, S. Bilgic Gazioglu, E. TuzunP004 - Adenosine a1 receptor dysfunction is associated with leukopenia: A possible mechanism for sepsis-induced leukopeniaR. Riff, O. Naamani, A. DouvdevaniP005 - Analysis of neutrophil by hyper spectral imaging - A preliminary reportR. Takegawa, H. Yoshida, T. Hirose, N. Yamamoto, H. Hagiya, M. Ojima, Y. Akeda, O. Tasaki, K. Tomono, T. ShimazuP006 - Chemiluminescent intensity assessed by eaa predicts the incidence of postoperative infectious complications following gastrointestinal surgeryS. Ono, T. Kubo, S. Suda, T. Ueno, T. IkedaP007 - Serial change of c1 inhibitor in patients with sepsis – A prospective observational studyT. Hirose, H. Ogura, H. Takahashi, M. Ojima, J. Kang, Y. Nakamura, T. Kojima, T. ShimazuP008 - Comparison of bacteremia and sepsis on sepsis related biomarkersT. Ikeda, S. Suda, Y. Izutani, T. Ueno, S. OnoP009 - The changes of procalcitonin levels in critical patients with abdominal septic shock during blood purificationT. Taniguchi, M. OP010 - Validation of a new sensitive point of care device for rapid measurement of procalcitoninC. Dinter, J. Lotz, B. Eilers, C. Wissmann, R. LottP011 - Infection biomarkers in primary care patients with acute respiratory tract infections – Comparison of procalcitonin and C-reactive proteinM. M. Meili, P. S. SchuetzP012 - Do we need a lower procalcitonin cut off?H. Hawa, M. Sharshir, M. Aburageila, N. SalahuddinP013 - The predictive role of C-reactive protein and procalcitonin biomarkers in central nervous system infections with extensively drug resistant bacteriaV. Chantziara, S. Georgiou, A. Tsimogianni, P. Alexandropoulos, A. Vassi, F. Lagiou, M. Valta, G. Micha, E. Chinou, G. MichaloudisP014 - Changes in endotoxin activity assay and procalcitonin levels after direct hemoperfusion with polymyxin-b immobilized fiberA. Kodaira, T. Ikeda, S. Ono, T. Ueno, S. Suda, Y. Izutani, H. ImaizumiP015 - Diagnostic usefullness of combination biomarkers on ICU admissionM. V. De la Torre-Prados, A. Garcia-De la Torre, A. Enguix-Armada, A. Puerto-Morlan, V. Perez-Valero, A. Garcia-AlcantaraP016 - Platelet function analysis utilising the PFA-100 does not predict infection, bacteraemia, sepsis or outcome in critically ill patientsN. Bolton, J. Dudziak, S. Bonney, A. Tridente, P. NeeP017 - Extracellular histone H3 levels are in...
BackgroundMethods to calculate energy expenditure (EE) based on CO2 measurements (EEVCO2) have been proposed as a surrogate to indirect calorimetry. This study aimed at evaluating whether EEVCO2 could be considered as an alternative to EE measured by indirect calorimetry.MethodsIndirect calorimetry measurements conducted for clinical purposes on 278 mechanically ventilated ICU patients were retrospectively analyzed. EEVCO2 was calculated by a converted Weir’s equation using CO2 consumption (VCO2) measured by indirect calorimetry and assumed respiratory quotients (RQ): 0.85 (EEVCO2_0.85) and food quotient (FQ; EEVCO2_FQ). Mean calculated EEVCO2 and measured EE were compared by paired t test. Accuracy of EEVCO2 was evaluated according to the clinically relevant standard of 5% accuracy rate to the measured EE, and the more general standard of 10% accuracy rate. The effects of the timing of measurement (before or after the 7th ICU day) and energy provision rates (<90 or ≥90% of EE) on 5% accuracy rates were also analyzed (chi-square tests).ResultsMean biases for EEVCO2_0.85 and EEVCO2_FQ were -21 and -48 kcal/d (p = 0.04 and 0.00, respectively), and 10% accuracy rates were 77.7 and 77.3%, respectively. However, 5% accuracy rates were 46.0 and 46.4%, respectively. Accuracy rates were not affected by the timing of the measurement, or the energy provision rates at the time of measurements.ConclusionsCalculated EE based on CO2 measurement was not sufficiently accurate to consider the results as an alternative to measured EE by indirect calorimetry. Therefore, EE measured by indirect calorimetry remains as the gold standard to guide nutrition therapy.
Early enteral nutrition is recommended for critically ill patients. Supplemental parenteral nutrition combined with enteral nutrition can be considered to cover the energy and protein targets when enteral nutrition alone fails to achieve the caloric goal. Whether such a combined nutritional support provides additional benefit on the overall outcome has to be proven in further studies on clinical outcome, including physical and cognitive functioning, quality of life, cost-effectiveness, and cost-utility.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.