Background/objective This study aimed to investigate the visual performance of a new extended depth-of-focus intraocular lens (EDOF-IOL). Subjects/methods In this multicenter, prospective, observational study, we enrolled 97 patients who underwent cataract surgery or refractive lens exchange with implantation of the Mini Well EDOF-IOL (SIFI, Italy). Patients underwent postoperatively the following examinations between 4 and 8 weeks after surgery: corrected distance visual acuity (CDVA), reading speed with Radner's chart, distance-corrected near visual acuity (DCNVA), defocus curve, contrast sensitivity, and haloes quantitative assessment. Results In the whole sample, the mean monocular CDVA and DCNVA were, respectively, 0.02 ± 0.07 logMAR and 0.38 ± 0.15 logRAD (logarithm of the reading acuity determination). In the 67 bilaterally implanted patients, binocular CDVA and DCNVA were better (0.00 ± 0.05 logMAR and 0.26 ± 0.13 logRAD) than the corresponding monocular values (p = 0.02 and p = 0.0002, respectively). Ninety-two percent of patients bilaterally implanted reached a binocular reading speed >80 words per minute at a 0.5 logRAD print size (corresponding to the common book print size). The defocus curves showed that the EDOF-IOL provided increased depth of focus through 2.0 D of defocus, with the best performance at 1.0 and 1.5 D. Contrast sensitivity was within normal limits at all spatial frequencies. The mean visual disturbance index was 0.08 ± 0.12, suggesting low night visual disturbances. Conclusions The new EDOF-IOL provided good visual acuity for distance, intermediate, and near vision, with no loss of contrast sensitivity and low risk of night visual disturbances.
In pseudophakic eyes, the Pentacam provides ACD values that do not statistically differ from those of ultrasound immersion biometry, on the condition that manual measurements are used rather than automatic ones.
A multicenter, nonrandomized, prospective, controlled study was conducted to evaluate, as perioperative prophylactic treatment, the anti-infective effectiveness of 0.66% povidone-iodine eye drops (IODIM®) against the bacterial flora of the conjunctival surface of patients who undergo cataract surgery. Eye drops containing 0.66% povidone-iodine were applied to the eye undergoing cataract surgery; the untreated contralateral eye was used as control. One hundred and twenty patients set to receive unilateral cataract surgery were enrolled in 5 Italian Ophthalmology Centers and pretreated for three days with 0.66% povidone-iodine eye drops. The contralateral eye, used as control, was left untreated. Conjunctival swabs of both eyes were collected at the baseline visit and after three days of treatment, just before the cataract surgery. A qualitative and quantitative microbiological analysis of bacterial presence was evaluated by means of bacterial culture, followed by identification. Methicillin resistance determination was also performed on staphylococci isolates. Bacterial load before and after treatment of the eye candidate for cataract surgery was evaluated and compared to the untreated eye. A reduction or no regrowth on the culture media of the bacterial load was observed in 100% of the study subjects. A great heterogenicity of bacterial species was found. The 0.66% povidone-iodine eye drops, used for three days prior to cataract surgery, were effective in reducing the conjunctival bacterial load. The 0.66% povidone-iodine eye drops (IODIM®) might represent a valid perioperative prophylactic antiseptic adjuvant treatment to protect the ocular surface from microbial contamination in preparation of the surgical procedure.
Purpose: The purpose of the study was to evaluate which ocular parameters have an impact on visual results obtained after an extended depth of focus (EDF) wavefront-designed intraocular lens (IOL). Setting: The study was conducted in three Italian centers (private practice in Lucca and two ambulatory surgical centers in Pisa and in Rome) from 01/09/2014 to 30/09/2015. Design: The study population included 178 eyes of 91 patients who had cataract surgery and implantation of an EDF wavefront - designed IOL (Mini Well Ready - SIFI Med Tech S.r.l.). Methods: Preoperative and postoperative refractive corneal spherical aberration (SA), ocular axial length, or anterior chamber depth were measured. Results: The majority of patients were spectacle-independent for near, intermediate, and distance vision and no one reported disturbing halos or glare. No overall significant differences were observed when stratifying anterior chamber depth (ACD) and ocular axial length (AL) by uncorrected distance visual acuity (UCDVA); p = 0.465 and 1.000 respectively, corrected distance visual acuity (CDVA); p = uncorrected near visual acuity (UCNVA); p = 1.000 and 0.728 respectively; p = 1.000 under both parameters and halos; 1.000 under both parameters. Still, there was a statistically significant difference when stratifying SA with 5 mm only by UDVA (p = 0.040). Conclusion: These results are consistent with similar outcomes in the scientific literature as measured with tests of visual acuity, either with or without optical correction. We also demonstrated that these IOLs can be used in myopic and hyperopic eyes, although it may be useful to evaluate the preoperative corneal SA to achieve better results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.