Mean Gradient (MG) elevation can be detected immediately after transcatheter aortic valve implantation (TAVI) or secondarily during follow-up. Comparisons and interactions between these two parameters and their impact on outcomes have not previously been investigated. This study aimed to identify incidence, influence on prognosis, and parameters associated with immediate high post-procedural mean transvalvular gradient (PPMG) and delayed mean gradient increase (6 to 12 months after TAVI, DMGI) in the FRANCE 2 (French Aortic National CoreValve and Edwards 2) registry. The registry includes all consecutive symptomatic patients with severe aortic stenosis who have undergone TAVI. Three groups were analyzed: (1) PPMG < 20 mmHg without DMGI > 10 mmHg (control); (2) PPMG < 20 mmHg with DMGI > 10 mmHg (Group 1); and (3) PPMG ≥ 20 mmHg (Group 2). From January 2010 to January 2012, 4201 consecutive patients were prospectively enrolled in the registry. Controls comprised 2078 patients. In Group 1(n = 131 patients), DMGI exceeded 10 mmHg in 5.6%, and was not associated with greater 4-years mortality than in controls (32.6% vs. 40.1%, p = 0.27). In Group 2 (n = 144 patients), PPMG was at least 20 mmHg in 6.1% and was associated with higher 4-year mortality (48.7% versus 40.1%, p = 0.005). A total of two-thirds of the patients with PPMG ≥ 20 mmHg had MG < 20 mmHg at 1 year, with mortality similar to the controls (39.2% vs. 40.1%, p = 0.73). Patients with PPMG > 20 mmHg 1 year post-TAVI had higher 4-years mortality than the general population of the registry, unlike patients with MG normalization.
Background: Left atrial appendage (LAA) closure has been well evaluated in the prevention of stroke in patients with atrial fibrillation. Device embolization remains one of the most common complications. To the best of our knowledge, there have been no reports of late discovery of LAA occluder device embolization at 1.5 years after implantation. Case presentation: We describe the case of a 77-year-old man who underwent uneventful LAA closure. Echocardiography performed the next day showed the device in place. The patient was discharged but was then lost to follow-up. 1.5 years later, he was admitted for ischemic stroke. Transesophageal echocardiography showed the absence of the occluder device in the LAA. Computed tomography scan of the abdomen showed the device in the abdominal aorta. Due to the high cardiovascular risk, the device was kept in place and the patient was treated medically. Conclusions: Per-procedural and late device embolization are not uncommon. Review of the literature however showed no report of late discovery of device embolization at 1.5 years. Follow-up echocardiography is mandatory for the detection of endothelialization or embolization.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.