Objective: To study the possible occurrence of left ventricular (LV) systolic and diastolic asynchrony in patients with systolic heart failure (HF) and narrow QRS complexes. Design: Prospective study. Setting: University teaching hospital. Patients: 200 subjects were studied by echocardiography. 67 patients had HF and narrow QRS complexes (< 120 ms), 45 patients had HF and wide QRS complexes (> 120 ms), and 88 served as normal controls. Interventions: Echocardiography with tissue Doppler imaging was performed using a six basal, six mid-segmental model. Main outcome measures: Severity and prevalence of systolic and diastolic asynchrony, as assessed by the maximal difference in time to peak myocardial systolic contraction (T S ) and early diastolic relaxation (T E ), and the standard deviation of T S (T S -SD) and of T E (T E -SD) of the 12 LV segments. Results: The mean (SD) maximal difference in T S (controls 53 (23) ms v narrow QRS 107 (54) ms v wide QRS 130 (51) ms, both p < 0.001 v controls) and in T S -SD (controls 17.0 (7.8) ms v narrow QRS 33.8 (16.9) ms v wide QRS 42.0 (16.5) ms, both p < 0.001 v controls) was prolonged in the narrow QRS group compared with normal controls. Similarly, the maximal difference in T E (controls 59 (19) ms v narrow QRS 104 (71) ms v wide QRS 148 (87) ms, both p < 0.001 v controls) and in T E -SD (controls 18.5 (5.8) ms v narrow QRS 33.3 (27.7) ms v wide QRS 48.6 (30.2) ms, both p < 0.001 v controls) was prolonged in the narrow QRS group. The prevalence of systolic and diastolic asynchrony was 51% and 46%, respectively, in the narrow QRS group, and 73% and 69%, respectively, in the wide QRS group. Stepwise multiple regression analysis showed that a low mean myocardial systolic velocity from the six basal LV segments and a large LV end systolic diameter were independent predictors of systolic asynchrony, while a low mean myocardial early diastolic velocity and QRS complex duration were independent predictors of diastolic asynchrony. Conclusions: LV systolic and diastolic mechanical asynchrony is common in patients with HF with narrow QRS complexes. As QRS complex duration is not a determinant of systolic asynchrony, it implies that assessment of intraventricular synchronicity is probably more important than QRS duration in considering cardiac resynchronisation treatment.
Background and Aims: Severe acute respiratory syndrome (SARS) is a virulent viral infection that affects a number of organs and systems. This study examined if SARS may result in cardiovascular complications. Methods and Results: 121 patients (37.5 (SD13.2) years, 36% male) diagnosed to have SARS were assessed continuously for blood pressure, pulse, and temperature during their stay in hopsital. Hypotension occurred in 61 (50.4%) patients in hospital, and was found in 28.1%, 21.5%, and 14.8% of patients during the first, second, and third week, respectively. Only one patient who had transient echocardiographic evidence of impaired left ventricular systolic function required temporary inotropic support. Tachycardia was present in 87 (71.9%) patients, and was found in 62.8%, 45.4%, and 35.5% of patients from the first to third week. It occurred independent of hypotension, and could not be explained by the presence of fever. Tachycardia was also present in 38.8% of patients at follow up. Bradycardia only occurred in 18 (14.9%) patients as a transient event. Reversible cardiomegaly was reported in 13 (10.7%) patients, but without clinical evidence of heart failure. Transient atrial fibrillation was present in one patient. Corticosteroid therapy was weakly associated with tachycardia during the second (x 2 = 3.99, p = 0.046) and third week (x 2 = 6.53, p = 0.01), although it could not explain tachycardia during follow up. Conclusions: In patients with SARS, cardiovascular complications including hypotension and tachycardia were common but usually self limiting. Bradycardia and cardiomegaly were less common, while cardiac arrhythmia was rare. However, only tachycardia persisted even when corticosteroid therapy was withdrawn.
The improvement of LV short-axis function but not long-axis function or torsion contributes to the improvement in LV global function and geometry at three-month follow up. A relatively preserved mean epsilon-circum of >or=6.5% might be useful to predict favourable responses after CRT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.