BackgroundInternational guidelines recommend that the decision threshold for troponin should be the 99th percentile of a normal population, or, if the laboratory assay is not sufficiently precise at this low level, the level at which the assay achieves a 10% or better coefficient of variation (CV). Our objectives were to examine US hospital laboratory troponin reports to determine whether either the 99th percentile or the 10% CV level were clearly indicated, and whether nonconcordance with these guidelines was a potential barrier to detecting clinically important microscopic or ‘microsize’ myocardial infarctions (MIs). To confirm past reports of the clinical importance of microsize MIs, we also contrasted in-hospital, 28-day and 1-year mortality among those with microsize and nonmicrosize MI.MethodsIn the REasons for Geographic And Racial Differences in Stroke national prospective cohort study (n=30,239), 1029 participants were hospitalized for acute coronary syndrome (ACS) between 2003–2009. For each case, we recorded all thresholds of abnormal troponin on the laboratory report and whether the 99th percentile or 10% CV value were clearly identified. All cases were expert adjudicated for presence of MI. Peak troponin values were used to classify MIs as microsize MI (< five times the lowest listed upper limit of normal) and nonmicrosize MI.ResultsParticipants were hospitalized at 649 acute care US hospitals, only 2% of whose lab reports clearly identified the 99th percentile or the 10% CV level; 52% of reports indicated an indeterminate range, a practice that is no longer recommended. There were 183 microsize MIs and 353 nonmicrosize MIs. In-hospital mortality tended to be lower in the microsize than in the nonmicrosize MI group (1.1 vs. 3.6%, p = 0.09), but 28-day and 1-year mortality were similar (2.5% vs. 2.7% [p = 0.93] and 5.2% vs. 4.3% [p = 0.64], respectively).ConclusionsCurrent practices in many US hospitals created barriers to the clinical recognition of microsize MI, which was common and clinically important in our study. Improved hospital troponin reporting is warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.