Summary Since the dual fluidized bed (DFB) system has been increasingly adopted for waste‐to‐energy gasification, a three‐dimensional computational fluid dynamics full‐loop model of a DFB cold flow system has been developed to predict the pressure and sand circulation rate (SCR) under various operating conditions. The pressure data were recorded at 18 specified points along the system height. In addition, the SCRs were determined at the two crucial positions connecting the riser and the gasifier and vice versa. The simulation results were then validated against the experimental data, taking into account the effects of the sand particle size (ds), the air inlet velocity in the riser (v0,riser), and the initial gasifier bed height (h0,gasifier). It could be observed in the riser that the flow structures of the smaller ds(s) were almost scattering patterns, while those of the bigger ones were mainly clusters. Compared with bigger ds(s), more homogeneous pressure distributions in the riser and higher bed expansion in the gasifier were obtained with smaller ones. A compromise between the system performance and pre‐treating cost for the feedstock particle sizes should be considered further to achieve the best system performance. On the other hand, the increases of the v0,riser and the h0,gasifier enhanced the gasifier bed pressure, facilitating the downward sand flow back to the riser via the LLS. Although some minor discrepancies existed between the simulation and experimental data, the predicted tendencies agreed well with the measured ones. It was also found that a system operating with ds = 500 μm, at v0,riser = 4.0 m/s and h0,gasifier = 0.25 m yielded stable flow characteristics and optimal global SCR. Moreover, some unexpected phenomena predicted and verified with the experimental observations could be avoided or minimized using suitable particle sizes of the feedstock and operating parameters. In sum, the better validation results with lower errors than our previous study, the more reasonable air‐sand flow patterns, and the substantial predictions of undesirable problems are the significant improvements of this study, providing valuable information for effectively designing and operating the practical DFB hot flow systems. Novelty Statement This study developed a 3D computational fluid dynamics full‐loop model of a DFB cold flow system for predicting the pressure and sand circulation rates under various operating conditions of particle size, inlet velocity, and initial bed height. The better validation results against the experimental data, the more reasonable air‐sand flow patterns, and the substantial predictions of undesirable problems are the significant improvements of this study, providing helpful information for designing and operating the DFB hot flow gasifiers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.