(1) Background: Prefabricated zirconia crowns are used to restore teeth in children. The purpose of this study was to evaluate the removal of these crowns with the erbium, chromium: yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser; (2) Methods: A total of 12 primary and 12 permanent teeth were prepared and prefabricated zirconia crowns were passively fitted and cemented with two resin modified glass-ionomer (RMGI) cements. Surface areas of prepared teeth and crowns were calculated. Crowns were removed using two laser settings: 4.5 Watts, 15 Hertz, 20 water/20 air, and 5 Watts, 15 Hertz, 50 water/50 air. The retrieval time and temperature changes were tested recorded. Data were analyzed using ANOVA with Tukey’s adjusted post hoc pairwise comparison t-test; (3) Results: The average time for crown removal was: 3 min, 47.7 s for permanent; and 2 min 5 s for primary teeth. The mean temperature changes were 2.48 °C (SD = 1.43) for permanent; and 3.14 °C (SD = 1.88) for primary teeth. The time to debond was significantly positively correlated with tooth inner surface area and volume, outer crown volume, and the cement volume; (4) Conclusions: Use of the Er,Cr:YSGG laser is an effective, safe and non-invasive method to remove prefabricated zirconia crowns cemented with RMGI cements from permanent and primary teeth.
(1) Background: Prefabricated zirconia crowns are used to restore teeth in children. The purpose of this study was to evaluate the removal of these crowns with the erbium, chromium: yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser; (2) Methods: Twelve primary and 13 permanent teeth were prepared and prefabricated zirconia crowns were passively fitted and cemented with two resin modified glass-ionomer cements. Surface areas of prepared teeth and crowns were calculated. Crowns were removed using two laser settings: 4.5 Watts, 15 Hertz, 20 water/ 20 air, and 5 Watts, 15 Hertz, 50 water/50 air. The retrieval time and temperature changes were tested recorded. Data were analyzed using ANOVA with Tuckey’s adjusted post hoc pairwise comparison t-test; (3) Results: The average time for crown removal was: 3 minutes, 47.7 seconds for permanent; and 2 minutes 5 seconds for primary teeth. The mean temperature changes were 2.48℃ (SD=1.43) for permanent; and 3.14℃ (SD=1.88) for primary teeth. The time to debond was significantly positively correlated with tooth inner surface area and volume, outer crown volume, and the cement volume; (4) Conclusions: Use of the Er,Cr:YSGG laser is an effective, safe and non-invasive method to remove prefabricated zirconia crowns cemented with RMGI cements from permanent and primary teeth.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.