Background Ultrasound is an essential imaging tool for evaluating physiological and pathological fetal or maternal conditions during pregnancy. Published data is limited with respect to the application of CEUS during pregnancy. CEUS has already been safely applied for assessing uteroplacental blood flow, cesarean scar pregnancy and invasive placenta percreta. CT and MRI scans during pregnancy must be thoroughly evaluated due to harmful ionizing radiation and cerebral gadolinium deposition, respectively. Purpose The aim of the present retrospective single-center study is to assess the diagnostic performance and safety of CEUS during pregnancy to evaluate hepatic lesions of unknown entity. Methods 6 pregnant patients who underwent CEUS between 2005 and 2014 (mean age: 32 years; mean weeks of pregnancy: 28 weeks) were included in this study. The applied contrast agent was a second-generation blood-pool agent (SonoVue®, Bracco, Milan, Italy). CEUS examinations were performed and interpreted by a single radiologist with experience since 2000 (EFSUMB Level 3). Results CEUS was safely performed on all included pregnant women without the occurrence of adverse fetal or maternal events. In the context of the present study, CEUS helped to safely differentiate hepatic metastases, focal nodular hyperplasia, atypical hemangioma, hepatic arteriovenous malformation and cystic echinococcosis. In two patients CEUS determined immediate therapy. Conclusion Although not clinically approved in obstetrics so far, CEUS is a safe imaging modality which, in addition to B-mode and color Doppler ultrasonography, may be applied during pregnancy for further medical indications and to provide helpful information.
Fusion imaging depicts an innovative technique that facilitates combining assets and reducing restrictions of advanced ultrasound and cross-sectional imaging. The purpose of the present retrospective study was to evaluate the role of fusion imaging for assessing hepatic and renal lesions. Between 02/2011–08/2020, 92 patients in total were included in the study, of which 32 patients had hepatic lesions, 60 patients had renal lesions. Fusion imaging was technically successful in all patients. No adverse side effects upon intravenous (i.v.) application of SonoVue® (Bracco, Milan, Italy) were registered. Fusion imaging could clarify all 11 (100%) initially as indeterminate described hepatic lesions by computed tomography/magnetic resonance imaging (CT/MRI). Moreover, 5/14 (36%) initially suspicious hepatic lesions could be validated by fusion imaging, whereas in 8/14 (57%), malignant morphology was disproved. Moreover, fusion imaging allowed for the clarification of 29/30 (97%) renal lesions initially characterized as suspicious by CT/MRI, of which 19/30 (63%) underwent renal surgery, histopathology revealed malignancy in 16/19 (84%), and benignity in 3/19 (16%). Indeterminate findings could be elucidated by fusion imaging in 20/20 (100%) renal lesions. Its accessibility and repeatability, even during pregnancy and in childhood, its cost-effectiveness, and its excellent safety profile, make fusion imaging a promising instrument for the thorough evaluation of hepatic and renal lesions in the future.
Objective Hepatocellular carcinoma (HCC) is the most common cause of primary liver cancer. A major part of diagnostic HCC work-up is based on imaging findings from sonography, computed tomography (CT), or magnetic resonance imaging (MRI) scans. Contrast-enhanced ultrasound (CEUS) allows for the dynamic assessment of the microperfusion pattern of suspicious liver lesions. This study aimed to evaluate the diagnostic value of CEUS compared with CT scans for assessing HCC. Methods We performed a retrospective, single-center study between 2004 and 2018 on 234 patients with suspicious liver lesions who underwent CEUS and CT examinations. All patients underwent native B-mode, color Doppler and CEUS after providing informed consent. Every CEUS examination was performed and interpreted by a single experienced radiologist (European Federation of Societies for Ultrasound in Medicine and Biology level 3). Results CEUS was performed on all included patients without occurrence of any adverse effects. CEUS showed a sensitivity of 94%, a specificity of 70%, a positive predictive value of 93% and a negative predictive value of 72% for analyzing HCC compared with CT as the diagnostic gold standard. Conclusions CEUS has an excellent safety profile and shows a high diagnostic accuracy in assessing HCC compared with corresponding results from CT scans.
Bosniak 2F renal cystic lesions feature morphologic characteristics between Bosniak I and III categories, the majority of which remain benign. However, a minor part of Bosniak 2F lesions may progress to malignancy. The purpose of this study was to assess Bosniak 2F cystic lesions during follow-up examinations by CEUS. One-hundred-and-twelve out of 364 patients with Bosniak 2F lesions underwent follow-up CEUS examinations between February 2008 and February 2020. Twelve out of 364 patients underwent renal surgery without follow-up CEUS. The progression rate of Bosniak 2F renal lesions detected by CEUS accounted for 7.1% (8/112 patients) after a mean of 12.9 months. The first follow-up CEUS revealed 75% of progressions (6/8), the remaining 25% (2/8) of progressions were detected during second follow-up CEUS. Underlying clear-cell renal cell carcinoma was histopathologically validated in 5/8 progressive complex cystic renal lesions. Stable sonomorphologic features were observed in 92.1% (104/112 patients). CEUS depicts a promising diagnostic imaging modality in the diagnostic work-up and follow-up of complex renal cystic lesions at higher spatial and temporal resolutions than CT or MRI. Its excellent safety profile, its easy and repeatable accessibility, and low financial costs render CEUS an attractive and powerful alternative imaging tool for monitoring complex renal cystic lesions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.