Background-Current evaluation of pulmonary hypertension (PH) in children involves measurement of pulmonary vascular resistance (PVR); however, PVR neglects important pulsatile components. Pulmonary artery (PA) input impedance and ventricular power (VP) include mean and pulsatile effects and have shown promise as alternative measures of vascular function. Here we report the utility of pulsed-wave (PW) Doppler-measured instantaneous flow and pressure measurements for estimation of input impedance and VP and use this method to develop a novel parameter: reactivity in compliance. Methods and Results-An in vitro model of the general pulmonary vasculature was used to obtain impedance and VP, measured by PW Doppler and a reference flow meter. The method was then tested in a preliminary clinical study in subjects with normal PA hemodynamics (nϭ4) and patients with PH undergoing reactivity evaluation (8 patients; 23 data points). In vitro results showed good agreement between the impedance spectra computed from both flowmeasurement methods. Excellent correlation was seen in vitro between actual resistance and the zero-frequency (Z o ) impedance value (r 2 ϭ0.984). Excellent agreement was also found between Z o and PVR in the clinical measurements (yϭ1.075xϩ0.73; rϭ0.993). Furthermore, total VP and VP/cardiac output increased significantly with hypertension (128.73 to 365.91 mW and 2.42 to 6.69 mW · mL Ϫ1 · s Ϫ1 , respectively). The first-harmonic value of impedance (Z 1 ) was used as a measure of compliance reactivity; older patients exhibited markedly less compliance reactivity than did younger patients. Conclusions-Input impedance and VP calculated from Doppler measurements and a single-catheter pressure measurement provide comprehensive characterization of PH and reactivity.
Background-Accurate determination of pulmonary vascular resistance (PVR) is an important component in the evaluation and treatment of pediatric patients with pulmonary hypertension. We developed a novel technique, based on the concept of flow propagation, to estimate PVR noninvasively. The hypothesis is that changes in PVR cause changes in the velocity propagation (Vel prop ) within the main pulmonary artery and that Vel prop can be quantified using color M-mode imaging. Methods and Results-We tested the hypothesis using mathematical modeling, in vitro experiments, and preliminary clinical studies. The mathematical model showed that pressure and velocity tracings are closely correlated in time and that 6 to 18 ms time resolution was needed to resolve propagation times within typical main pulmonary artery lengths (2 to 5 cm
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.