BackgroundClinicians need a practical, objective test of postural control that is sensitive to mild neurological disease, shows experimental and clinical validity, and has good test-retest reliability. We developed an instrumented test of postural sway (ISway) using a body-worn accelerometer to offer an objective and practical measure of postural control.MethodsWe conducted two separate studies with two groups of subjects. Study I: sensitivity and experimental concurrent validity. Thirteen subjects with early, untreated Parkinson’s disease (PD) and 12 age-matched control subjects (CTR) were tested in the laboratory, to compare sway from force-plate COP and inertial sensors. Study II: test-retest reliability and clinical concurrent validity. A different set of 17 early-to-moderate, treated PD (tested ON medication), and 17 age-matched CTR subjects were tested in the clinic to compare clinical balance tests with sway from inertial sensors. For reliability, the sensor was removed, subjects rested for 30 min, and the protocol was repeated. Thirteen sway measures (7 time-domain, 5 frequency-domain measures, and JERK) were computed from the 2D time series acceleration (ACC) data to determine the best metrics for a clinical balance test.ResultsBoth center of pressure (COP) and ACC measures differentiated sway between CTR and untreated PD. JERK and time-domain measures showed the best test-retest reliability (JERK ICC was 0.86 in PD and 0.87 in CTR; time-domain measures ICC ranged from 0.55 to 0.84 in PD and from 0.60 to 0.89 in CTR). JERK, all but one time-domain measure, and one frequency measure were significantly correlated with the clinical postural stability score (r ranged from 0.50 to 0.63, 0.01 < p < 0.05).ConclusionsBased on these results, we recommend a subset of the most sensitive, reliable, and valid ISway measures to characterize posture control in PD: 1) JERK, 2) RMS amplitude and mean velocity from the time-domain measures, and 3) centroidal frequency as the best frequency measure, as valid and reliable measures of balance control from ISway.
Timed Up and Go (TUG) test is a widely used clinical paradigm to evaluate balance and mobility. Although TUG includes several complex subcomponents, namely: sit-to-stand, gait, 180° turn and turn-to-sit; the only outcome is the total time to perform the task. We have proposed an instrumented TUG, called iTUG, using portable inertial sensors to improve TUG in several ways: automatic detection and separation of subcomponents, detailed analysis of each one of them and a higher sensitivity than TUG. Twelve subjects in early stages of Parkinson's Disease (PD) and twelve age matched control subjects were enrolled. Stop-watch measurements did not show a significant difference between the two groups. The iTUG, however, showed a significant difference in cadence between early PD and control subjects (111.1±6.2 vs. 120.4±7.6 step/min, p < 0.006) as well as in angular velocity of arm-swing (123±32.0 vs. 174.0 ± 50.4 °/sec, p < 0.005), turning duration (2.18 ± 0.43 vs. 1.79 ± 0.27 seconds, p < 0.023) and time to perform turn-to-sits (2.96 ± 0.68 vs. 2.40 ± 0.33 seconds, p < 0.023). By repeating the tests for a second time, the testretest reliability of iTUG was also evaluated. Among the subcomponents of iTUG, gait, turning and turn-to-sit were the most reliable and sit-to-stand was the least reliable.
The Timed Up and Go (TUG) test has been used to assess balance and mobility in Parkinson’s Disease (PD). However, it is not known if this test is sensitive to subtle abnormalities present in early stages of the disease, when balance and gait problems are not clinically evident but may be detected with instrumented analysis of movement. We hypothesize that postural transitions and arm swing during gait will be the most sensitive characteristics of the TUG for early PD. In the present study, we instrumented the TUG test (iTUG) using portable inertial sensors, and extended the walking distance from 3 meters (traditional TUG) to 7 meters. Twelve subjects with early-to-moderate, untreated PD and 12 healthy individuals participated. Our findings show that although the stopwatch measure of TUG duration did not detect abnormalities in early-to-mid stage PD, the peak arm swing velocity on the more affected side, average turning velocity, cadence and peak trunk rotation velocity were significantly slower. These iTUG parameters were also correlated with the UPDRS Motor Scale. Thus, the iTUG test is sensitive to untreated PD and could potentially detect progression of PD and response to symptomatic and disease-modifying treatments.
While several studies have shown that subjects with advanced Parkinson's disease (PD) exhibit abnormalities in sway parameters during quiet standing, abnormalities of postural sway associated with untreated PD have not been reported. Although not clinically apparent, we hypothesized that spontaneous sway in quiet stance is abnormal in people with untreated PD. We examined 13 subjects, recently diagnosed with PD, who were not yet taking any anti-parkinsonian medications and 12 healthy, age-matched control subjects. Postural sway was measured with a linear accelerometer on the posterior trunk (L5 level) and compared with traditional forceplate measures of sway. Subjects stood for two minutes under two conditions: eyes open (EO) and eyes closed (EC). One of the most discriminative measures of postural changes in subjects with untreated PD was the increased ‘JERK’ of lower trunk in the EO condition, measured with the accelerometer. Root mean square and the frequency dispersion of postural sway in the EO condition also discriminated sway in untreated PD subjects compared to controls subjects. We conclude that accelerometer-based sway metrics could be used as objective measures of postural instability in untreated PD. Accelerometer-based analysis of spontaneous sway may provide a powerful tool for early clinical trials and for monitoring the effects of treatment of balance disorders in subjects with PD.
Objective measures of postural control that are sensitive to Parkinson's Disease (PD) progression would improve patient care and accelerate clinical trials. Although measures of postural sway during quiet stance in untreated PD have been shown to differ from age-matched control subjects, it is not known if sway measures change with disease progression in early PD. In this pilot study, we asked whether accelerometer-based metrics of sway could provide a practical tool for monitoring progression of postural dyscontrol in people with untreated or newly treated PD. We examined 13 subjects with PD and 12 healthy, age-matched control subjects. The PD subjects had been recently diagnosed and had not started any antiparkinsonian medications at the baseline session. All subjects were tested 3-to-6 months and 12 months after the baseline session. Subjects were asked to stand quietly for two minutes while wearing an inertial sensor on their posterior trunk that measured trunk linear acceleration. Our results suggested that objective sway measures deteriorated over one year despite minimal changes in UPDRS motor scores. Medio-lateral (ML) sway measures were more sensitive than antero-posterior sway measures in detecting progression. The ML JERK was larger in the PD group than the control group across all three testing sessions. The ML sway dispersion and ML sway velocity were also significantly higher in PD compared to control subjects by the 12-month evaluation. It is feasible to measure progression of PD prior to onset of treatment using accelerometer-based measures of quiet standing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.