Purpose: To evaluate the mid-term effects of implant of dynamic neutralization system (Dynesys) on disc tissue in patients with lumbar discopathy, through the quantification of glycosaminoglycans (GAG) concentration, both in treated and adjacent levels, by analysis of delayed gadolinium-enhanced MRI contrast (dGEMRIC) images. Materials and Methods:Ten patients with low back pain underwent the dGEMRIC diagnostic protocol before, 6-months and after 2 years from surgery. Each patient was also evaluated with visual analog (VAS), Oswestry, and Prolo scales both at presurgery and during follow-up. From dGEMRIC images, a DT1 parametric map was obtained for each disc, as quantitative indicator of its GAG concentration, and divided in 13 sectors, which were classified at presurgery as normal or abnormal, based on a 70-ms threshold. Evolution of DT1 was studied during the follow-up.Results: Nine of ten patients completed the follow-up. VAS, Oswestry, and Prolo grades showed an improvement. This was accompanied by a reduction of DT1 in abnormal segments while normal segments showed a pattern of initial worsening at 6 months, followed by an improvement after 2 years. Conclusion:Our study confirmed the improvement in clinical evaluation, and for the first time related this to the changes in discs GAG concentration.
A post contrast magnetic resonance imaging study has been performed in a wide population of low back pain patients to investigate which radiological and phenotypic characteristics influence the penetration of the contrast agent in lumbar discs in vivo. 37 patients affected by different pathologies (disc herniation, spondylolisthesis, foraminal stenosis, central canal stenosis) were enrolled in the study. The selected population included 26 male and 11 female subjects, with a mean age of 42.4±9.3 years (range 18–60). Magnetic resonance images of the lumbar spine were obtained with a 1.5 T scanner (Avanto, Siemens, Erlangen, Germany) with a phased-array back coil. A paramagnetic non–ionic contrast agent was injected with a dose of 0.4 ml/kg. T1-weighted magnetic resonance images were subsequently acquired at 5 time points, 5 and 10 minutes, 2, 4 and 6 hours after injection. Endplates presented clear enhancement already 5 minutes after injection, and showed an increase in the next 2 hours followed by a decrease. At 5 and 10 minutes, virtually no contrast medium was present inside the intervertebral disc; afterwards, enhancement significantly increased. Highly degenerated discs showed higher enhancement in comparison with low and medium degenerated discs. Discs classified as Pfirrmann 5 showed a statistically significant higher enhancement than Pfirrmann 1, 2 and 3 at all time points but the first one, possibly due to vascularization. Disc height collapse and Modic changes significantly increased enhancement. Presence of endplate defects did not show any significant influence on post contrast enhancement, but the lack of a clear classification of endplate defects as seen on magnetic resonance scans may be shadowing some effects. In conclusion, disc height, high level of degeneration and presence of Modic changes are factors which increase post contrast enhancement in the intervertebral disc. The effect of age could not be demonstrated.
BackgroundThe study of lung parenchyma anatomical modification is useful to estimate dose discrepancies during the radiation treatment of Non-Small-Cell Lung Cancer (NSCLC) patients. We propose and validate a method, based on free-form deformation and mutual information, to elastically register planning kVCT with daily MVCT images, to estimate lung parenchyma modification during Tomotherapy.MethodsWe analyzed 15 registrations between the planning kVCT and 3 MVCT images for each of the 5 NSCLC patients. Image registration accuracy was evaluated by visual inspection and, quantitatively, by Correlation Coefficients (CC) and Target Registration Errors (TRE). Finally, a lung volume correspondence analysis was performed to specifically evaluate registration accuracy in lungs.ResultsResults showed that elastic registration was always satisfactory, both qualitatively and quantitatively: TRE after elastic registration (average value of 3.6 mm) remained comparable and often smaller than voxel resolution. Lung volume variations were well estimated by elastic registration (average volume and centroid errors of 1.78% and 0.87 mm, respectively).ConclusionsOur results demonstrate that this method is able to estimate lung deformations in thorax MVCT, with an accuracy within 3.6 mm comparable or smaller than the voxel dimension of the kVCT and MVCT images. It could be used to estimate lung parenchyma dose variations in thoracic Tomotherapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.