Fulcrum higher than bending higher than traction with the patient UGA is the order of radiographs for better predicting flexibility and correction in curves between 40 degrees and 65 degrees. Flexibility obtained at traction radiographs with the patient UGA is clearly better in numerical values, and closer to the amount of surgical correction than the amount of flexibility at fulcrum and side-bending radiographs for curves larger than 65 degrees, although not statistically significant as a result of the small number of patients in this group. However, pedicle screw instrumentation provides even more correction than the traction radiographs with the patient UGA. Thus, traction radiographs with the patient UGA may show much better flexibility, especially in more than 65 degrees and rigid curves.
The purpose of this study was to assess the accuracy of injections of dye into the first extensor compartment of the wrist using three different techniques in 150 wrists in 75 fresh cadavers. To compare injections, 50 wrists from 25 cadavers were used for each technique. After the injections, the first extensor compartment was dissected and the dispersion of dye around the abductor pollicis longus and extensor pollicis brevis tendons was investigated. In 72 % of all the wrists, acrylic dye was dispersed into one compartment containing both the abductor pollicis longus and extensor pollicis brevis tendons, but in 28% of the wrists there was a separate compartment for extensor pollicis brevis and dye entered only one of the compartments (14% for each compartment). For accurate injections, we think the injections should be made separately over the two tendons, to allow for the possibility of a septum within the compartment.
The expectations of both the patient and surgeon have been greatly revised in the last 10 years with the introduction of pedicle screws (PS) in spinal surgery. In this study, we have retrospectively evaluated and compared the results of PS instrumentation and the Hybrid System (HS), the latter consists of pedicle screws, sublaminar wire and hooks. The mean follow-up period was 60.1 months (range: 49-94 months) for the patients of the HS group and 29.3 months (range: 24-35 months) for those of the PS group. In the HS group, pedicle screws were used at the thoracolumbar junction and lumbar vertebra, the bilateral pediculotransverse claw hook configuration was used at the cranial end of the instrumentation, sublaminar wire was used on the concave side of the apical region and the compressive hook was used on the convex side. In the PS group, PS were used on the concave sides at all levels and on the convex side of the cranial and caudal end of instrumentation, in the transition zone and at the apex. The two groups were comparable for variables such as mean age, preoperative Cobb angle, thoracic kyphosis angle, lordosis angle, coronal balance, flexibility of the curve, apical vertebra rotation (AVR), apical vertebra rotation (AVT) and the number of vertebrae included in the fusion (p>0.05). The parameters of values of correction, ratio of correction loss, AV derotation, AVT correction ratio, amount of blood loss, operation time, postoperative global coronal and sagittal balance, thoracic kyphosis angle and lumbar lordosis angle were measured at the last follow-up and used for comparing the HS and PS groups. There was no statistically significant difference between the groups for correction ratio, postoperative coronal balance, postoperative thoracic kyphosis and lumbar lordosis angle, operation time, amount of blood loss and number of fixation points (p>0.05) The difference for the ratio of correction loss, AV derotation angle and the AVT correction ratio at the last follow-up visit and for the total follow-up period between the groups was found to be statistically significant (p<0.05). Although it is possible to obtain a similar amount of correction by either instrumentation system, the loss of correction seems to be lower with the more rigid PS construction. The PS system also has a stronger effect on vertebral bodies, thereby providing better AV de-rotation. There was no significant difference (p>0.05) between the groups in terms of correction rate, postoperative coronal and sagittal balance, operation time, blood loss and number of fixation points. This may indicate that anchor points are more important than the use -or not -of screws. Correction durability and AV de-rotation was better with PS instrumentation, while AVT was better corrected by HS instrumentation (p<0.05). We propose that the reason for the better correction of AVT with HS instrumentation is the forceful translation offered by the sublaminar wire at the apical region, while the reason for the better correction durability of the PS instr...
We retrospectively studied the cases with tuberculous spondylitis of thoracolumbar region with two or more levels of involvement that underwent posterior instrumentation and fusion and anterior fusion with titanium mesh following anterior decompression using simultaneous successive posterior-anterior-posterior surgery. Among all patients with tuberculous spondylitis accompanied by medium or severe kyphosis, 20 patients who underwent simultaneous successive decompression, fusion and instrumentation with posterior-anterior-posterior surgery between 1999 and 2004 were included in the study. Patients were evaluated for fusion formation and neurological and functional status. Kyphosis angles were measured at early and long-term follow-up. Antituberculosis chemotherapy was initiated in all patients and continued for 9 months; initially as quadruple therapy for 3 months, and then as triple therapy. Average follow-up period was 52.7 months (range 37-94). Solid fusion was achieved in all patients. All patients returned to their previous occupation; 75% (15 subjects) with mild pain or no pain and 15% (3 subjects) with major limitations. There were 11 patients with neurological deficit, 9 of these achieved complete neurological recoveries. Regarding kyphosis angle, an average 35.1°correction (84.8%) was obtained in postoperative period (p \ 0.001) and there was no significant correction loss during the follow-up period (p \ 0.05). There were no grafts or instrumentation-related stabilization problems. In subjects with tuberculous spondylitis with involvements at two or more levels accompanied by medium and severe kyphosis, decompression, fusion and instrumentation by simultaneous successive posterior-anterior-posterior surgery is an effective and safe management method for effective kyphosis correction with high fusion rates.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.