Open globe injuries complicated with the presence of an intraocular foreign body mostly affect young males and represent a vision threatening condition. We presented the case of a 48-year-old male who presented to our emergency service due to ocular pain and blurred vision in his right eye. A metallic foreign body situated between 1 and 12 o'clock, near the corneoscleral limbus, that perforated the cornea, the iris, the anterior capsule of the lens and the lens, was detected at the slit-lamp examination. We decided to immediately remove the foreign body that was approximately 20 mm long. The following day, traumatic cataract had already developed, so we performed cataract extraction. Despite the dimensions of the intraocular foreign body, the retina was attached and there were no sign of retinal tears or vitreous haemorrhage. The proper management in this case led to good results in spite of the dimensions of the intraocular foreign body. Abbreviations: IOFB = Intraocular Foreign Body, IOL = Intraocular Lens, PVR = Proliferative Vitreo-Retinopathy
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.