These results suggest that it may be desirable to implement 16-bit MAR-corrected images for treatment planning purposes, which can provide a more accurate dosimetric approach coupled with improved visualization by suppression of CT artifacts.
Projected light fields are used on treatment simulators and teletherapy treatment units to delineate the size and position of the radiation beam. Any discrepancy between these fields will lead to a systematic field placement error, with possibly serious implications with regard to the accuracy of the delivered dose distribution in the patient. Conventionally, film has been used for regular quality control tests of light and radiation field congruence, but this is a time consuming method and is not suitable for daily checks. A new method is described that uses a specially designed test phantom, a video-based electronic portal imaging device and a personal computer to test for radiation and light field congruence on treatment accelerators. This method consists of aligning the test phantom in the light field of a treatment linac and acquiring an electronic portal image. A computer program then automatically analyzes the image and determines the degree of congruence between the two fields. The final result of the test is a go, warning, or no go decision depending on the extent of misalignment between the light and radiation fields. Two algorithms were tested for reproducibility (<0.4 mm), sensitivity to noise (<0.2 mm), and positional accuracy (<0.4 mm) and are shown to give results comparable to the conventional film method. Daily testing of field congruence over a period of 84 days demonstrated differences in the results determined by the two algorithms of less than 0.1 +/- 0.2 mm (standard deviation) at 6 MV and 0.22 +/- 0.13 mm at 23 MV. Routine testing is possible as the effort and time required are minimal, and the test can be performed during daily routine start-up procedures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.