BACKGROUND AND PURPOSE: High-resolution vessel wall MR imaging is prone to slow-flow artifacts, particularly when gadolinium shortens the T1 relaxation time of blood. This study aimed to determine the optimal preparation pulses for contrast-enhanced high-resolution vessel wall MR imaging. MATERIALS AND METHODS:Fifty patients who underwent both motion-sensitized driven equilibrium and delay alternating with nutation for tailored excitation (DANTE) preparation pulses with contrast-enhanced 3D-T1-FSE were retrospectively included. Qualitative analysis was performed using a 4-grade visual scoring system for black-blood performance in the small-sized intracranial vessels, overall image quality, severity of artifacts, and the degree of blood suppression in all cortical veins as well as transverse sinuses. Quantitative analysis of the M1 segment of the MCA was also performed. RESULTS:The qualitative analysis revealed that motion-sensitized driven equilibrium demonstrated a significantly higher black-blood score than DANTE in contrast-enhanced 3D-T1-FSE of the A3 segment (3.90 versus 3.58, P , .001); M3 (3.72 versus 3.26, P = .004); P2 to P3 (3.86 versus 3.64, P = .017); the internal cerebral vein (3.72 versus 2.32, P , .001); and overall cortical veins (3.30 versus 2.74, P , .001); and transverse sinuses (2.82 versus 2.38, P , .001). SNR lumen , contrast-to noise ratio wall-lumen , and SNR wall in the M1 vessel were not significantly different between the 2 preparation pulses (all, P . .05).CONCLUSIONS: Motion-sensitized driven equilibrium demonstrated improved blood suppression on contrast-enhanced 3D-T1-FSE in the small intracranial arteries and veins compared with DANTE. Motion-sensitized driven equilibrium is a useful preparation pulse for high-resolution vessel wall MR imaging to decrease venous contamination and suppress slow-flow artifacts when using contrast enhancement.ABBREVIATIONS: BB ¼ black-blood; CE ¼ contrast-enhanced; CNR ¼ contrast-to-noise ratio; DANTE ¼ delay alternating with nutation for tailored excitation; HR-VWI ¼ high-resolution vessel wall MR imaging; ICV ¼ internal cerebral vein; MSDE ¼ motion-sensitized driven equilibrium
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.