Ionic thermometers have been tested in a nuclear reactor with attention to the steepness of the ionic conductivity jump and the influence of a glass container on the accuracy of the temperature measurements. It was found that, at the neutron fluxes up to 1.5×1018 m−2 s−1 (thermal) and 3×1018 m−2 s−1 (fast) in a light water reactor, the change of conductivity jump slope is negligible or nil for an ionic thermometer filled by HgI2, i.e., at 256.0±0.2 °C. The need to use boron-free glass was confirmed. The impact on the accuracy of the temperature point indication in a nuclear reactor core is discussed, as well as obvious inertness of the melting process mechanism to the intense irradiation field.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.