Patent ductus arteriosus (PDA) is common congenital heart disease which may require treatment as transcatheter percutaneous device closure (PDA device closure) or surgical ligation in symptomatic full-term patients. Surgical ligation is an invasive procedure and has more complications especially in the neonates. Problems in PDA device closure are difficult vascular access, manipulation of catheters and sheath, residual shunts, residual obstruction of major arteries etc and these complications increase in low birth weight babies, but it is a less invasive procedure and has fewer complications than surgery, so should be tried in low birth weight patients also. We are presenting a case of 3 kg infant with large PDA (8 mm) presented with failure to thrive, lower respiratory tract infection and heart failure. He successfully underwent PDA device closure with 10 × 12 mm Cocoon PDA device. To the best of our knowledge, this is the first case of the use of such a large device in a 3 kg child with good results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.