Prophylactic dynamic screw fixation (DSF) of clinically and radiographically unaffected hips of 34 patients with a contralateral slipped capital femoral epiphysis and no evidence of an endocrinopathy or systemic disorder was performed using a single cannulated screw. Follow-up ranged from 2 to 12 years (average, 5.4 years). There was no case of perioperative complication and no avascular necrosis or chondrolysis occurred. No preslip or slip became apparent. In all 34 hips, no tendency toward premature closure of the epiphysis could be observed, no growth disturbance including greater trochanteric overgrowth, coxa brevis, or coxa vara was noted. This study supports the prophylactic treatment of the asymptomatic hip, using a simple and safe fixation method.
We reviewed 45 patients on average 14.7 years after surgery for rupture of the anterior cruciate ligament. The aim of the study was to compare the reliability of the Lachman test to evaluation of knee laxity with the KT 1000 arthrometer and the ultrasound-assisted Lachman test. Forty-five knees were examined with the Lachman test: 12 knees showed no sign of instability; 20 had a + positive Lachman test with a hard end point; 6 with a + positive test had no end point and were rated as unstable; a +2 Lachman test was found in 7 knees. With the KT 1000 Arthrometer 44 knees were examined: 30 knees were graded as stable according to the criteria of Daniel; 14 knees were unstable. We used the ultrasound-guided Lachman test in 44 knees. Taking only the side-to-side difference into account, 37 knees were stable and 7 unstable. According to Gruber, a single translation greater than 4 mm is also a sign of instability. Therefore, 12 knees were unstable, although 6 of these knees were rated as stable, taking the side-to-side difference into account. Comparing the two instrument measurements, all knees with ultrasound-rated instability on the basis of side-to-side measurements were also rated as unstable with the KT 1000 arthrometer. Only half of the knees rated as unstable because of a single translation greater than 4 mm with the ultrasound technique were rated as unstable with the KT 1000 arthrometer. Our results show that the accuracy of the Lachman test is as good as the instrument evaluation if the end point is taken into consideration. A positive Lachman test indicating anterior knee laxity is one where the soft end point is as described by Torg et al. Both instrument measurements are accurate in indicating anterior knee laxity, but only if they are used by an experienced examiner. Using the side-to-side measurements, the sensitivity of the KT 1000 arthrometer is higher. If only single translations greater than 4 mm without a significant side-to-side difference with the ultrasound technique are interpreted as anterior knee instability, then some knees will be rated as unstable, although both the clinical and KT 1000 arthrometer examinations prove them to be stable. We believe that only a side-to-side difference with the instrument techniques should be interpreted as knee laxity. Borderline positive measurements should only be used together with the clinical findings. Both instrument measurements can help to improve the quality of the clinical examination if the examiners are inexperienced. If instrument measurements are required, we believe that the ultrasound technique is easy and cheap to perform. Nevertheless, we believe that instrument measurements of anterior knee laxity are not necessary if a thorough clinical examination is performed, taking the end point of the Lachman test into consideration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.