A modified colorimetric enzyme-linked immunosorbant assay (ELISA) for Salmonella detection was compared to the standard culture method of the Bacteriological Analytical Manual/Association of Official Analytical Chemists (BAM/AOAC) using 20 artificially contaminated foods (1,200 test samples). The modifications to the current methodology consisted of an elevated incubation temperature of 42°C for the tetrathionate selective broth and M-broth postenrichments, as well as addition of 10 μg/ml novobiocin to the M-broth. The microtiter plate as not agitated during assay incubation, and centrifugation steps were eliminated from the protocol. This modified ELISA method was at least as productive as the standard AOAC culture method for the food samples tested. No false-positive reactions were encountered. The false-negative incidence was 1.5% for the immunoassay and 5.3% by the AOAC cultural method. The incidence of agreement between the methods was 96.7%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.