Objectives To evaluate the 3-and 5-year incidence of posterior capsule opacification (PCO) and neodymium-doped yttrium aluminium garnet (Nd:YAG) capsulotomy in patients following cataract surgery, comparing results for different single-piece acrylic hydrophilic and hydrophobic monofocal intraocular lens (IOL) models and other patient factors. Patients and methods Electronic medical record data collected from seven United Kingdom (UK) National Health Service (NHS) ophthalmology clinics for routine, age-related (≥65 years) cataract surgeries that implanted single-piece acrylic monofocal IOLs during 2010-2013 were used to calculate 3-and 5-year incidence of Nd:YAG and PCO. IOL models of Alcon Acrysof, AMO Tecnis, Bausch & Lomb (B & L) Akreos, LenStec Softec, and Rayner Flex were analyzed. Pairwise comparisons were conducted between AcrySof IOLs and other IOLs using Bonferroni adjustment for multiplicity. Multivariate analyses were conducted adjusting for known confounders. Results The incidence of Nd:YAG capsulotomy ranged between 2.4-12.6% at 3 years and 5.8-19.3% at 5 years postcataract surgery. Similarly, the incidence of PCO ranged between 4.7-18.6% at 3 years and 7.1-22.6% at 5 years. When comparing all of the single-piece IOLs, AcrySof demonstrated the lowest incidence rates for both PCO and Nd:YAG (P < 0.001 for each comparison). From adjusted logistic regression analysis, AcrySof were associated with lower 3-and 5-year odds of Nd:YAG and PCO incidence. Conclusions Following cataract surgery with single-piece monofocal IOLs different incidence rates of PCO were observed with different IOLs. AcrySof IOLs were associated with significantly lower incidence of PCO requiring Nd:YAG treatment over periods of 3 and 5 years.
The findings highlight that up to 70% of the total costs associated with MS are not routinely counted. These "hidden" costs are higher in Ireland than the rest of Europe, due in part to significantly lower levels of workforce participation, a higher likelihood of permanent workforce withdrawal, and higher levels of informal care needs. The relationship between disease progression and costs emphasize the societal importance of managing and slowing the progression of the illness.
Objectives To investigate the associations between different single-piece monofocal intraocular lenses (IOLs) and neodymium-doped yttrium aluminum garnet laser (Nd:YAG) capsulotomy incidence 3 years after cataract surgery in a Spanish cohort. Methods This is a longitudinal retrospective cohort study. Data were extracted from the electronic medical records of two large regional hospitals in Spain. Patients aged ≥65 years receiving cataract surgery with placement of five different IOLs and with ≥6 months of baseline data were included. We report the Nd:YAG capsulotomy incidence 3 years post cataract surgery, and the survival plot over the 3 years of follow-up time. The associated adjusted (age, gender, and diabetic retinopathy) multivariate analysis with odds ratios (ORs) and 95% CIs is also presented. Results The cohort (53% female, mean age 75 ± 5.9 years) included 14,519 eyes (Alcon AcrySof = 2968, AJL LLASY60 = 1776, Medicontur Bi-flex = 5176, Zeiss Asphina = 4478, and IOL Tech Stabibag = 121). Of these, 8293 were retained until 3-year follow-up. At 3 years after cataract surgery, the Nd:YAG capsulotomy incidence was 5% for Alcon AcrySof, while it ranged from 21.2% to 31.1% for the other IOLs (p < 0.0001 for each comparison). The odds for Nd:YAG capsulotomy were significantly higher (p < 0.0001) for other IOLs compared with those of Alcon AcrySof (ORs = 8.85, 5.86, 5.74, 5.21 for AJL LLASY60, Medicontur Bi-flex, IOL Tech Stabibag, and Zeiss Asphina, respectively). Conclusions The lower Nd:YAG capsulotomy rates for Alcon AcrySof IOLs compared to the other IOLs support the importance of lens choice in reducing patient burden and treatment costs.
Objective The purpose of this study was to evaluate the impact of different intraocular lens materials (IOL) and optic edge designs on the incidence of Nd:YAG laser capsulotomy. Methods Randomized controlled trials (RCTs) reporting incidence of Nd:YAG capsulotomy in patients with monofocal IOLs were identified for systematic literature review (SLR) using Cochrane methodology. A network meta-analysis was conducted under a Bayesian framework. Mean hazard ratios (HRs), 95% credible intervals, and one-sided p-values were estimated for Nd:YAG capsulotomy incidence by comparing AcrySof IOLs with a group of non-AcrySof hydrophobic acrylic, hydrophilic acrylic, silicone, and PMMA IOLs. Sensitivity analysis was conducted comparing the risk of Nd:YAG capsulotomy between sharp- and round-edged designs of the above IOLs. Results AcrySof IOLs had a lower risk of Nd:YAG capsulotomy compared to hydrophobic acrylic (HR: 2.68; 95% CrI: 1.41, 4.77; p < 0.01), hydrophilic acrylic (HR: 7.54; 95% CrI: 4.24, 14.06; p < 0.001), PMMA (HR: 3.64, 95% CrI: 1.87, 6.33; p < 0.001), and silicone (HR: 1.13; 95% CrI: 0.59, 1.91; p <0.1) IOLs. The risk for Nd:YAG was highest among sharp-edged IOLs for hydrophilic acrylic IOLs (HR: 9.32; 95% CrI: 4.32, 19.29; p < 0.01), followed by other hydrophobic acrylic (HR: 2.91; 95% CrI: 1.27, 5.88; p < 0.01), silicone (HR: 0.838; 95% CrI: 0.328, 1.74; p = 0.69), and PMMA (HR: 0.39; 95% CrI: 0.042, 1.49; p = 0.93) IOLs, compared to AcrySof. Acrysof IOLs had a lower risk of Nd:YAG compared to PMMA (HR: 3.25; 95% CrI: 1.21, 7.37; p < 0.01) and silicone, round edge IOLs (HR: 3.84; 95% CrI: 1.08, 10.64; p = 0.015). Conclusion The risk of Nd:YAG capsulotomy is lower in eyes implanted with AcrySof IOLs compared to non-AcrySof hydrophobic or hydrophilic acrylic IOLs. Sharp-edged AcrySof, PMMA, and silicone IOLs are comparable in terms of reducing the risk of Nd:YAG laser capsulotomy.
OBJECTIVES: Posterior capsular opacification (PCO) is the most common complication after cataract surgery and its development is associated with several factors, including lens material and design of implanted intraocular lens (IOL). Nd:YAG laser capsulotomy is the only effective treatment for PCO, however, the procedure places a financial burden on health care systems and has been shown to be associated with a number of complications. A systematic literature review (SLR) was conducted to complile evidence on the complications associated with Nd:YAG capsulotomy for PCO after cataract surgery. METHODS: A systematic literature search was conducted on Embase®, MEDLINE®, MEDLINE®-In Process, and Cochrane from January 1996 through August 2017. Articles were selected if they included age-related cataract patients, monofocal IOL implantation for cataract surgery and underwent Nd:YAG capsulotomy for PCO. Complications asssociated with Nd:YAG capsulotomy reported in both RCTs and non-RCTs were reviewed. RESULTS: 19 studies in total (16 non-RCTs and 3 RCTs) fulfilled the inclusion criteria. In non-RCTs, reports of retinal detachment (6 studies) ranged from 0.31% to 7.6%. While incidence of cystoid macular edema (CME) (5 studies) ranged from 0.2% to 7.9%. The included RCTs reported IOL pitting between 14.8% and 19.2%. One RCT reported the incidence of CME (5.8%), retinal detachment (2.5%), increased IOP (12.5%), and uveitis (10%). Other complications reported were as follows: Hyaloid phase rupture, corneal burn, hyphema, posterior vitreous detachment, vitreous in anterior chamber, severe PCO due to high laser energy and vitreous prolapse. CONCLUSIONS: The available evidence confirms that treatment of PCO with Nd:YAG is associated with a notable clinical burden due to complications associated with the procedure, such as retinal detachment and CME. Therefore, reducing the requirement for Nd:YAG capsulotomy to treat PCO, via the correct choice of IOL, will subsequently play a role in improving health outcomes for cataract patients, while translating into savings for national healthcare systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.