The heat flux and destruction and removal efficiency (DRE) measurements have been made on 100, 150 and 200 mm diameter plasma reactors to optimize the performance. The DRE was measured for pressure and gas atomization techniques of waste injection using both argon and CO 2 gases. As a result, the design of the reactor was optimized and the waste throughput was increased by ∼17% with improved destruction performance. The 150 mm diameter reactor was found to perform better using gas atomization of feed injection using carbon dioxide at the given power and waste feed rate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.