The paper presents the results of experimental research related to the process of cutting of t = 3 mm and t = 6 mm thick RVS 1.4301 (AISI 304, EN X5CrNi18-10) stainless steel using a fiber and CO2 lasers. The correct selection of technological parameters and the maintenance of the machines in the right technical condition allow obtaining very high quality of the cut edge, which will not require additional mechanical treatment. However, this is a complex issue. Appropriate control of the cutting process requires knowledge about the impact of individual parameters on the process and the quality of the cut edge. The influence of selected parameters and conditions of the laser cutting process on the technological quality of the obtained product was determined. The laser power and cutting speed had a significant influence on the output factors for two cutting techniques.For cutting material with a thickness of t = 3 mm with a CO2 laser, the highest quality of the cut edge was obtained using the power values P = 4200-4300 W and cutting speed v = 2100 mm/min. For the thickness t = 6 mm, the speed values should be approximately set in range v = 1600-1800 mm/min. The power value should be selected in a range from P = 3700 W to P = 4200 W. For a fiber laser with a material thickness of t = 3 mm, the best results were obtained using speeds in the range v = 2000-3300 mm/min. For the thickness of t = 6 mm, the cutting speed must be higher and in the range v = 3500-4000 mm/min while maintaining the power of about P = 4500-4800 W. The conducted experimental research can be useful on production lines in the aspect of the correct selection of technological parameters of the process due to the adopted energy and quality criteria.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.